{"title":"北极自动监测站能量采集仿真","authors":"D. Pimentel, P. Musílek, A. Knight","doi":"10.1109/EPEC.2010.5697232","DOIUrl":null,"url":null,"abstract":"Automatic Arctic monitoring stations are usually deployed in remote and isolated areas. Supplying the electricity required for the operation of a monitoring station can be done in two ways: stored energy is carried on-site (fuel, battery), or energy is harvested from the environment and converted to an electrical current. Energy harvesting is an attractive solution that requires careful planning. Simulation of energy sources, energy transducers, power converters, storage devices, and components of the monitoring station is employed for component sizing and for testing worst-case scenarios. As the availability of each energy source is dependent on the geographic location, data from specialized meteorological databases is used as input for the simulator.","PeriodicalId":393869,"journal":{"name":"2010 IEEE Electrical Power & Energy Conference","volume":"404 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Energy harvesting simulation for Automatic Arctic monitoring stations\",\"authors\":\"D. Pimentel, P. Musílek, A. Knight\",\"doi\":\"10.1109/EPEC.2010.5697232\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Automatic Arctic monitoring stations are usually deployed in remote and isolated areas. Supplying the electricity required for the operation of a monitoring station can be done in two ways: stored energy is carried on-site (fuel, battery), or energy is harvested from the environment and converted to an electrical current. Energy harvesting is an attractive solution that requires careful planning. Simulation of energy sources, energy transducers, power converters, storage devices, and components of the monitoring station is employed for component sizing and for testing worst-case scenarios. As the availability of each energy source is dependent on the geographic location, data from specialized meteorological databases is used as input for the simulator.\",\"PeriodicalId\":393869,\"journal\":{\"name\":\"2010 IEEE Electrical Power & Energy Conference\",\"volume\":\"404 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Electrical Power & Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2010.5697232\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Electrical Power & Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2010.5697232","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

自动北极监测站通常部署在偏远和孤立的地区。监测站运行所需的电力供应有两种方式:就地储存能量(燃料、电池),或者从环境中获取能量并转化为电流。能量收集是一个有吸引力的解决方案,但需要仔细规划。对能源、能量换能器、功率变换器、存储设备和监测站组件进行仿真,以确定组件尺寸和测试最坏情况。由于每种能源的可用性取决于地理位置,因此使用来自专门气象数据库的数据作为模拟器的输入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Energy harvesting simulation for Automatic Arctic monitoring stations
Automatic Arctic monitoring stations are usually deployed in remote and isolated areas. Supplying the electricity required for the operation of a monitoring station can be done in two ways: stored energy is carried on-site (fuel, battery), or energy is harvested from the environment and converted to an electrical current. Energy harvesting is an attractive solution that requires careful planning. Simulation of energy sources, energy transducers, power converters, storage devices, and components of the monitoring station is employed for component sizing and for testing worst-case scenarios. As the availability of each energy source is dependent on the geographic location, data from specialized meteorological databases is used as input for the simulator.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信