{"title":"内置电流传感器IDDQ测试","authors":"Bin Xue, D. Walker","doi":"10.1109/DBT.2004.1408945","DOIUrl":null,"url":null,"abstract":"A practical built-in current sensor (BICS) design is described in this paper. This sensor system is able to monitor the IDDQ at a resolution level of 10 muA. This system can translate the current level into a digital signal, with scan chain readout. There is no system performance degradation for this sensor and its power dissipation is kept at a very low level. With the help of a self-calibration circuit, the sensor can maintain its accuracy and achieve a clock rate of over 1 GHz, for a measurement time of a few milliseconds","PeriodicalId":407554,"journal":{"name":"Proceedings. 2004 IEEE International Workshop on Current and Defect Based Testing (IEEE Cat. No.04EX1004)","volume":"571 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"Built-in current sensor for IDDQ test\",\"authors\":\"Bin Xue, D. Walker\",\"doi\":\"10.1109/DBT.2004.1408945\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A practical built-in current sensor (BICS) design is described in this paper. This sensor system is able to monitor the IDDQ at a resolution level of 10 muA. This system can translate the current level into a digital signal, with scan chain readout. There is no system performance degradation for this sensor and its power dissipation is kept at a very low level. With the help of a self-calibration circuit, the sensor can maintain its accuracy and achieve a clock rate of over 1 GHz, for a measurement time of a few milliseconds\",\"PeriodicalId\":407554,\"journal\":{\"name\":\"Proceedings. 2004 IEEE International Workshop on Current and Defect Based Testing (IEEE Cat. No.04EX1004)\",\"volume\":\"571 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. 2004 IEEE International Workshop on Current and Defect Based Testing (IEEE Cat. No.04EX1004)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DBT.2004.1408945\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 2004 IEEE International Workshop on Current and Defect Based Testing (IEEE Cat. No.04EX1004)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DBT.2004.1408945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A practical built-in current sensor (BICS) design is described in this paper. This sensor system is able to monitor the IDDQ at a resolution level of 10 muA. This system can translate the current level into a digital signal, with scan chain readout. There is no system performance degradation for this sensor and its power dissipation is kept at a very low level. With the help of a self-calibration circuit, the sensor can maintain its accuracy and achieve a clock rate of over 1 GHz, for a measurement time of a few milliseconds