D. Bryant, Sourabh Ravindran, N. Magotra, S. Northrup
{"title":"基于胸戴式加速度计的心脏监测系统的实时实现","authors":"D. Bryant, Sourabh Ravindran, N. Magotra, S. Northrup","doi":"10.1109/MWSCAS.2010.5548828","DOIUrl":null,"url":null,"abstract":"This paper presents the real-time implementation of an approach for monitoring the heart using a single accelerometer. The implementation described is based on an algorithmic approach that has been shown to successfully remove motion artifacts from accelerometer based heart signal measurements. A driving factor in this project is the need for low-cost heart rate monitoring as part of a personal monitoring system for use world-wide. The digital signal processor (DSP) chosen for the implementation was Texas Instruments (TI) TMS320C5505 DSP in order to reduce the power requirement of the specific implementation thereby conserving battery life. The TMS320C5505 CPU can operate on 1.05V and the chip architecture has been highly optimized for energy efficiency.","PeriodicalId":245322,"journal":{"name":"2010 53rd IEEE International Midwest Symposium on Circuits and Systems","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Real-time implementation of a chest-worn accelerometer based heart monitoring system\",\"authors\":\"D. Bryant, Sourabh Ravindran, N. Magotra, S. Northrup\",\"doi\":\"10.1109/MWSCAS.2010.5548828\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the real-time implementation of an approach for monitoring the heart using a single accelerometer. The implementation described is based on an algorithmic approach that has been shown to successfully remove motion artifacts from accelerometer based heart signal measurements. A driving factor in this project is the need for low-cost heart rate monitoring as part of a personal monitoring system for use world-wide. The digital signal processor (DSP) chosen for the implementation was Texas Instruments (TI) TMS320C5505 DSP in order to reduce the power requirement of the specific implementation thereby conserving battery life. The TMS320C5505 CPU can operate on 1.05V and the chip architecture has been highly optimized for energy efficiency.\",\"PeriodicalId\":245322,\"journal\":{\"name\":\"2010 53rd IEEE International Midwest Symposium on Circuits and Systems\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 53rd IEEE International Midwest Symposium on Circuits and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSCAS.2010.5548828\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 53rd IEEE International Midwest Symposium on Circuits and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSCAS.2010.5548828","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文提出了一种利用单个加速度计实时监测心脏的方法。所描述的实现基于一种算法方法,该算法已被证明可以成功地从基于加速度计的心脏信号测量中去除运动伪影。该项目的一个驱动因素是需要低成本的心率监测作为全球范围内使用的个人监测系统的一部分。数字信号处理器(DSP)选择德州仪器(TI) TMS320C5505 DSP,以减少特定实现的功率需求,从而节省电池寿命。TMS320C5505 CPU的工作电压为1.05V,芯片架构在能效方面进行了高度优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-time implementation of a chest-worn accelerometer based heart monitoring system
This paper presents the real-time implementation of an approach for monitoring the heart using a single accelerometer. The implementation described is based on an algorithmic approach that has been shown to successfully remove motion artifacts from accelerometer based heart signal measurements. A driving factor in this project is the need for low-cost heart rate monitoring as part of a personal monitoring system for use world-wide. The digital signal processor (DSP) chosen for the implementation was Texas Instruments (TI) TMS320C5505 DSP in order to reduce the power requirement of the specific implementation thereby conserving battery life. The TMS320C5505 CPU can operate on 1.05V and the chip architecture has been highly optimized for energy efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信