利用能检测解剖图像源位置的幻像评估脑磁图源估计

H. Tanaka, T. Kimura, A. Kodabashi, T. Fujimoto, M. Usui, K. Takeuchi, T. Matsumoto, Y. Higashi
{"title":"利用能检测解剖图像源位置的幻像评估脑磁图源估计","authors":"H. Tanaka, T. Kimura, A. Kodabashi, T. Fujimoto, M. Usui, K. Takeuchi, T. Matsumoto, Y. Higashi","doi":"10.1109/ITAB.2007.4407393","DOIUrl":null,"url":null,"abstract":"Cerebral nerve activity estimated by means of magnetoencephalography (MEG) is usually evaluated by fusion with anatomical images such as MRI, X-ray CT. Therefore, in order to diagnose using MEG measurement results, it is very important to consider not only accuracy of MEG source estimation but also total accuracy including fusion with these anatomical images. In this report, we introduce a phantom which is capable of detecting the source location from these anatomical images as well as MEG measurement, and show this phantom can be used for the evaluation of MEG source estimation including fusion with anatomical images.","PeriodicalId":129874,"journal":{"name":"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine","volume":"249 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of MEG source estimation using a phantom which is also capable of detecting source location of anatomical images\",\"authors\":\"H. Tanaka, T. Kimura, A. Kodabashi, T. Fujimoto, M. Usui, K. Takeuchi, T. Matsumoto, Y. Higashi\",\"doi\":\"10.1109/ITAB.2007.4407393\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cerebral nerve activity estimated by means of magnetoencephalography (MEG) is usually evaluated by fusion with anatomical images such as MRI, X-ray CT. Therefore, in order to diagnose using MEG measurement results, it is very important to consider not only accuracy of MEG source estimation but also total accuracy including fusion with these anatomical images. In this report, we introduce a phantom which is capable of detecting the source location from these anatomical images as well as MEG measurement, and show this phantom can be used for the evaluation of MEG source estimation including fusion with anatomical images.\",\"PeriodicalId\":129874,\"journal\":{\"name\":\"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine\",\"volume\":\"249 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITAB.2007.4407393\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITAB.2007.4407393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过脑磁图(MEG)估计的脑神经活动通常是通过与MRI、x线CT等解剖图像融合来评估的。因此,为了利用脑磁图测量结果进行诊断,不仅要考虑脑磁图源估计的准确性,而且要考虑与这些解剖图像融合的总准确性。在本报告中,我们介绍了一种能够从这些解剖图像中检测源位置和MEG测量的幻像,并证明了该幻像可以用于评估MEG源估计,包括与解剖图像的融合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of MEG source estimation using a phantom which is also capable of detecting source location of anatomical images
Cerebral nerve activity estimated by means of magnetoencephalography (MEG) is usually evaluated by fusion with anatomical images such as MRI, X-ray CT. Therefore, in order to diagnose using MEG measurement results, it is very important to consider not only accuracy of MEG source estimation but also total accuracy including fusion with these anatomical images. In this report, we introduce a phantom which is capable of detecting the source location from these anatomical images as well as MEG measurement, and show this phantom can be used for the evaluation of MEG source estimation including fusion with anatomical images.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信