{"title":"操作过程中接触传感器定位能力的比较","authors":"J. Son, M. Cutkosky, R. Howe","doi":"10.1109/IROS.1995.526145","DOIUrl":null,"url":null,"abstract":"This paper presents an experimental comparison of tactile array versus force-torque sensing for localizing contact during manipulation. The manipulation tasks involved rotating and translating objects using a planar two fingered manipulator. A pin and a box were selected as limiting cases of point and line contact against a cylindrical robot finger tip. Force-torque contact sensing results suffered from difficulties in calibration, transient forces, and low grasp force. Tactile array sensing was immune to these problems, and the effect of shear loading was only noticeable for a simple centroid algorithm. The results show that with care, both of these sensing schemes can determine the contact location within a millimeter during real manipulation tasks.","PeriodicalId":124483,"journal":{"name":"Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"53","resultStr":"{\"title\":\"Comparison of contact sensor localization abilities during manipulation\",\"authors\":\"J. Son, M. Cutkosky, R. Howe\",\"doi\":\"10.1109/IROS.1995.526145\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an experimental comparison of tactile array versus force-torque sensing for localizing contact during manipulation. The manipulation tasks involved rotating and translating objects using a planar two fingered manipulator. A pin and a box were selected as limiting cases of point and line contact against a cylindrical robot finger tip. Force-torque contact sensing results suffered from difficulties in calibration, transient forces, and low grasp force. Tactile array sensing was immune to these problems, and the effect of shear loading was only noticeable for a simple centroid algorithm. The results show that with care, both of these sensing schemes can determine the contact location within a millimeter during real manipulation tasks.\",\"PeriodicalId\":124483,\"journal\":{\"name\":\"Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"53\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IROS.1995.526145\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IROS.1995.526145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of contact sensor localization abilities during manipulation
This paper presents an experimental comparison of tactile array versus force-torque sensing for localizing contact during manipulation. The manipulation tasks involved rotating and translating objects using a planar two fingered manipulator. A pin and a box were selected as limiting cases of point and line contact against a cylindrical robot finger tip. Force-torque contact sensing results suffered from difficulties in calibration, transient forces, and low grasp force. Tactile array sensing was immune to these problems, and the effect of shear loading was only noticeable for a simple centroid algorithm. The results show that with care, both of these sensing schemes can determine the contact location within a millimeter during real manipulation tasks.