{"title":"光伏和公用事业线路的自动互连系统","authors":"E. Murata, E. Harada","doi":"10.1109/INTLEC.1994.396581","DOIUrl":null,"url":null,"abstract":"This paper describes a new interconnecting system for numerous photovoltaics and utility line. In this system, each of the DC-DC converters derives the maximum power from each of photovoltaics for any daylight strength. Outputs of converters are connected to a DC bus line. The inverter sends power from the DC bus line to the utility line. The inverter is automatically synchronized to the utility line by means of a phase locked loop which includes the inner resistance of the DC bus line. A power factor controller combined with the phase locked loop makes power factor unity by changing the output voltage of the inverter corresponding to total output power of the photovoltaics.<<ETX>>","PeriodicalId":123164,"journal":{"name":"Proceedings of Intelec 94","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Automatic interconnecting system for photovoltaics and utility line\",\"authors\":\"E. Murata, E. Harada\",\"doi\":\"10.1109/INTLEC.1994.396581\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new interconnecting system for numerous photovoltaics and utility line. In this system, each of the DC-DC converters derives the maximum power from each of photovoltaics for any daylight strength. Outputs of converters are connected to a DC bus line. The inverter sends power from the DC bus line to the utility line. The inverter is automatically synchronized to the utility line by means of a phase locked loop which includes the inner resistance of the DC bus line. A power factor controller combined with the phase locked loop makes power factor unity by changing the output voltage of the inverter corresponding to total output power of the photovoltaics.<<ETX>>\",\"PeriodicalId\":123164,\"journal\":{\"name\":\"Proceedings of Intelec 94\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Intelec 94\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1994.396581\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Intelec 94","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1994.396581","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Automatic interconnecting system for photovoltaics and utility line
This paper describes a new interconnecting system for numerous photovoltaics and utility line. In this system, each of the DC-DC converters derives the maximum power from each of photovoltaics for any daylight strength. Outputs of converters are connected to a DC bus line. The inverter sends power from the DC bus line to the utility line. The inverter is automatically synchronized to the utility line by means of a phase locked loop which includes the inner resistance of the DC bus line. A power factor controller combined with the phase locked loop makes power factor unity by changing the output voltage of the inverter corresponding to total output power of the photovoltaics.<>