{"title":"光伏电站并联电容器组设计","authors":"A. Kalyuzhny, B. Reshef, G. Yehuda, Gladbin David, P. Koulbekov, T. Day","doi":"10.1109/EUROCON.2013.6625156","DOIUrl":null,"url":null,"abstract":"In order to ensure a large-scale application of PV generators in MV distribution system without unacceptable voltage changes due to drops of PV power output a simple, low-cost solution is developed. The solution includes operation of PV with predetermined leading power factor and addition of a capacitor bank in parallel to PV plant in order to compensate the reactive power absorbed by the PV inverters. Application of the developed negative-sequence current difference method for the unbalance protection of the capacitor banks enables to achieve a compact and cost-reduced design of the banks connected in parallel to PV power plants.","PeriodicalId":136720,"journal":{"name":"Eurocon 2013","volume":"286 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Design of capacitor bank in parallel to photovoltaic power plant\",\"authors\":\"A. Kalyuzhny, B. Reshef, G. Yehuda, Gladbin David, P. Koulbekov, T. Day\",\"doi\":\"10.1109/EUROCON.2013.6625156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to ensure a large-scale application of PV generators in MV distribution system without unacceptable voltage changes due to drops of PV power output a simple, low-cost solution is developed. The solution includes operation of PV with predetermined leading power factor and addition of a capacitor bank in parallel to PV plant in order to compensate the reactive power absorbed by the PV inverters. Application of the developed negative-sequence current difference method for the unbalance protection of the capacitor banks enables to achieve a compact and cost-reduced design of the banks connected in parallel to PV power plants.\",\"PeriodicalId\":136720,\"journal\":{\"name\":\"Eurocon 2013\",\"volume\":\"286 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eurocon 2013\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUROCON.2013.6625156\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eurocon 2013","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUROCON.2013.6625156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of capacitor bank in parallel to photovoltaic power plant
In order to ensure a large-scale application of PV generators in MV distribution system without unacceptable voltage changes due to drops of PV power output a simple, low-cost solution is developed. The solution includes operation of PV with predetermined leading power factor and addition of a capacitor bank in parallel to PV plant in order to compensate the reactive power absorbed by the PV inverters. Application of the developed negative-sequence current difference method for the unbalance protection of the capacitor banks enables to achieve a compact and cost-reduced design of the banks connected in parallel to PV power plants.