启发式控制和故障检测的数据方法组合[心脏辅助装置]

J. Boston, L. Baloa, Dehou Liu, M. Simaan, S. Choi, J. Antaki
{"title":"启发式控制和故障检测的数据方法组合[心脏辅助装置]","authors":"J. Boston, L. Baloa, Dehou Liu, M. Simaan, S. Choi, J. Antaki","doi":"10.1109/CCA.2000.897406","DOIUrl":null,"url":null,"abstract":"Heart assist devices based on turbo-hydrodynamic methods of pumping are smaller, more efficient, and more reliable than the reciprocating, pulsatile methods used in current devices. However, they pose a more difficult control problem because the appropriate setpoint for the pump speed depends on preload and afterload, which vary with time. The pump should be run as fast as possible to maximize cardiac output, but ventricular suction can occur when the device attempts to pump more blood than is available. Suction must be detected quickly and the pump speed reduced before suction damages the heart. In many cases, control algorithms must rely on limited or no measurement of hemodynamic variables. We describe a method for suction detection and pump speed control based only on measurements of pump current, speed, and, when available, pump flow. Four heuristic indices that can detect suction are used, and the data are fused to decide whether suction is present If suction is present, speed is immediately reduced. If suction is not present, the indices are used as inputs to a fuzzy controller to adjust the pump speed so that the pump is operating just below the speed that induces suction. Data fusion techniques for suction detection based on Bayesian, fuzzy logic and Dempster-Shafer theory were evaluated. Fusion techniques based on fuzzy logic and Dempster-Shafer theory provide a measure of uncertainty in the fused result. This uncertainty measure can be used in the control process, and it can also be used to identify faults in pump operation.","PeriodicalId":108537,"journal":{"name":"Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Combination of data approaches to heuristic control and fault detection [heart assist devices]\",\"authors\":\"J. Boston, L. Baloa, Dehou Liu, M. Simaan, S. Choi, J. Antaki\",\"doi\":\"10.1109/CCA.2000.897406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heart assist devices based on turbo-hydrodynamic methods of pumping are smaller, more efficient, and more reliable than the reciprocating, pulsatile methods used in current devices. However, they pose a more difficult control problem because the appropriate setpoint for the pump speed depends on preload and afterload, which vary with time. The pump should be run as fast as possible to maximize cardiac output, but ventricular suction can occur when the device attempts to pump more blood than is available. Suction must be detected quickly and the pump speed reduced before suction damages the heart. In many cases, control algorithms must rely on limited or no measurement of hemodynamic variables. We describe a method for suction detection and pump speed control based only on measurements of pump current, speed, and, when available, pump flow. Four heuristic indices that can detect suction are used, and the data are fused to decide whether suction is present If suction is present, speed is immediately reduced. If suction is not present, the indices are used as inputs to a fuzzy controller to adjust the pump speed so that the pump is operating just below the speed that induces suction. Data fusion techniques for suction detection based on Bayesian, fuzzy logic and Dempster-Shafer theory were evaluated. Fusion techniques based on fuzzy logic and Dempster-Shafer theory provide a measure of uncertainty in the fused result. This uncertainty measure can be used in the control process, and it can also be used to identify faults in pump operation.\",\"PeriodicalId\":108537,\"journal\":{\"name\":\"Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162)\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCA.2000.897406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCA.2000.897406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

基于涡轮流体动力泵送方法的心脏辅助装置比当前设备中使用的往复式脉动方法更小、更高效、更可靠。然而,它们带来了一个更困难的控制问题,因为泵转速的适当设定值取决于预负荷和后负荷,而预负荷和后负荷随时间而变化。泵应尽可能快地运转以使心输出量最大化,但当设备试图泵出更多的血液时,可能会发生心室吸血。在抽吸损害心脏之前,必须迅速检测到抽吸并降低泵速。在许多情况下,控制算法必须依赖于有限的或没有血液动力学变量的测量。我们描述了一种仅基于泵电流、速度和可用泵流量测量的吸力检测和泵转速控制方法。使用四个可以检测吸力的启发式指标,并将数据融合以确定是否存在吸力。如果存在吸力,则速度立即降低。如果吸力不存在,则将这些指标用作模糊控制器的输入,以调整泵的速度,使泵的运行速度刚好低于诱导吸力的速度。对基于贝叶斯、模糊逻辑和邓普斯特-谢弗理论的吸力检测数据融合技术进行了评价。基于模糊逻辑和邓普斯特-谢弗理论的融合技术为融合结果提供了一种不确定性度量。这种不确定性度量既可用于控制过程,也可用于识别泵运行中的故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combination of data approaches to heuristic control and fault detection [heart assist devices]
Heart assist devices based on turbo-hydrodynamic methods of pumping are smaller, more efficient, and more reliable than the reciprocating, pulsatile methods used in current devices. However, they pose a more difficult control problem because the appropriate setpoint for the pump speed depends on preload and afterload, which vary with time. The pump should be run as fast as possible to maximize cardiac output, but ventricular suction can occur when the device attempts to pump more blood than is available. Suction must be detected quickly and the pump speed reduced before suction damages the heart. In many cases, control algorithms must rely on limited or no measurement of hemodynamic variables. We describe a method for suction detection and pump speed control based only on measurements of pump current, speed, and, when available, pump flow. Four heuristic indices that can detect suction are used, and the data are fused to decide whether suction is present If suction is present, speed is immediately reduced. If suction is not present, the indices are used as inputs to a fuzzy controller to adjust the pump speed so that the pump is operating just below the speed that induces suction. Data fusion techniques for suction detection based on Bayesian, fuzzy logic and Dempster-Shafer theory were evaluated. Fusion techniques based on fuzzy logic and Dempster-Shafer theory provide a measure of uncertainty in the fused result. This uncertainty measure can be used in the control process, and it can also be used to identify faults in pump operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书