{"title":"儿童刚性支气管镜检查技术问题的特点","authors":"M. Ö. Kuzdan","doi":"10.46648/gnj.386","DOIUrl":null,"url":null,"abstract":"Aim: Foreign body aspiration in the respiratory tract in children is a vital problem treated with rigid bronchoscopy (RB). In our study, technical problems and solutions of problems detected during RB were evaluated. Methods: Between August 2019-March 2021, 42 cases, which are operated due to foreign body aspiration, are analyzed in terms of age, gender, nature, and location of foreign body, complications, and technical problems. Results: 42 child patients (20 girls, 22 boys) were admitted to our clinic due to foreign body aspiration the respiratory tract ranged in average age from 1-16 years (average 4.6). Three of the foreign bodies were removed from the right main bronchi, 7 from the left main bronchi, and 4 from the trachea. Thirty-six were organic and 6 were inorganic. Human error was detected in 8 cases, instrument error in 27 cases, device error in 4 cases, and multiple errors in 3 cases. Conclusion: In attempts where tools and devices are used extensively, there are undesirable events and complications due to errors. We believe that analyzing error reports to reduce them is preventative","PeriodicalId":394509,"journal":{"name":"Gevher Nesibe Journal IESDR","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Features of Technical Problems in Pediatric Rigid Bronchoscopy\",\"authors\":\"M. Ö. Kuzdan\",\"doi\":\"10.46648/gnj.386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: Foreign body aspiration in the respiratory tract in children is a vital problem treated with rigid bronchoscopy (RB). In our study, technical problems and solutions of problems detected during RB were evaluated. Methods: Between August 2019-March 2021, 42 cases, which are operated due to foreign body aspiration, are analyzed in terms of age, gender, nature, and location of foreign body, complications, and technical problems. Results: 42 child patients (20 girls, 22 boys) were admitted to our clinic due to foreign body aspiration the respiratory tract ranged in average age from 1-16 years (average 4.6). Three of the foreign bodies were removed from the right main bronchi, 7 from the left main bronchi, and 4 from the trachea. Thirty-six were organic and 6 were inorganic. Human error was detected in 8 cases, instrument error in 27 cases, device error in 4 cases, and multiple errors in 3 cases. Conclusion: In attempts where tools and devices are used extensively, there are undesirable events and complications due to errors. We believe that analyzing error reports to reduce them is preventative\",\"PeriodicalId\":394509,\"journal\":{\"name\":\"Gevher Nesibe Journal IESDR\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gevher Nesibe Journal IESDR\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46648/gnj.386\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gevher Nesibe Journal IESDR","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46648/gnj.386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Features of Technical Problems in Pediatric Rigid Bronchoscopy
Aim: Foreign body aspiration in the respiratory tract in children is a vital problem treated with rigid bronchoscopy (RB). In our study, technical problems and solutions of problems detected during RB were evaluated. Methods: Between August 2019-March 2021, 42 cases, which are operated due to foreign body aspiration, are analyzed in terms of age, gender, nature, and location of foreign body, complications, and technical problems. Results: 42 child patients (20 girls, 22 boys) were admitted to our clinic due to foreign body aspiration the respiratory tract ranged in average age from 1-16 years (average 4.6). Three of the foreign bodies were removed from the right main bronchi, 7 from the left main bronchi, and 4 from the trachea. Thirty-six were organic and 6 were inorganic. Human error was detected in 8 cases, instrument error in 27 cases, device error in 4 cases, and multiple errors in 3 cases. Conclusion: In attempts where tools and devices are used extensively, there are undesirable events and complications due to errors. We believe that analyzing error reports to reduce them is preventative