{"title":"心脏植入式电子装置电极电磁干扰检测","authors":"J. Morava, A. Richter, J. Eichler","doi":"10.23919/MEASUREMENT47340.2019.8780035","DOIUrl":null,"url":null,"abstract":"The study deals with the interdisciplinary topic of the electromagnetic compatibility of the cardiac implantable electronic devices (CIEDs) that are used in patients with a defect of the heart conduction system. This article points on the issues of electromagnetic interference (EMI) detected on electrodes of cardiostimulation device. The detection of disturbance signals depends on many aspects related to electrode choice, device placement, it's configuration and programming. The aim of the study is the analysis of the pacemaker response in the presence of an external source of the disturbance fields. We point to possible risks of its interaction and discuss the mechanisms that can influence the pacemaker sensitivity to EMI. Finally, we present one real case and an experiment of the exposure of the cardiostimulation system to a low-frequency time-varying field. The emphasis of this session is put on physical and technical aspects, but it is also related to the medical part of the issue.","PeriodicalId":129350,"journal":{"name":"2019 12th International Conference on Measurement","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices\",\"authors\":\"J. Morava, A. Richter, J. Eichler\",\"doi\":\"10.23919/MEASUREMENT47340.2019.8780035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study deals with the interdisciplinary topic of the electromagnetic compatibility of the cardiac implantable electronic devices (CIEDs) that are used in patients with a defect of the heart conduction system. This article points on the issues of electromagnetic interference (EMI) detected on electrodes of cardiostimulation device. The detection of disturbance signals depends on many aspects related to electrode choice, device placement, it's configuration and programming. The aim of the study is the analysis of the pacemaker response in the presence of an external source of the disturbance fields. We point to possible risks of its interaction and discuss the mechanisms that can influence the pacemaker sensitivity to EMI. Finally, we present one real case and an experiment of the exposure of the cardiostimulation system to a low-frequency time-varying field. The emphasis of this session is put on physical and technical aspects, but it is also related to the medical part of the issue.\",\"PeriodicalId\":129350,\"journal\":{\"name\":\"2019 12th International Conference on Measurement\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 12th International Conference on Measurement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/MEASUREMENT47340.2019.8780035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 12th International Conference on Measurement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/MEASUREMENT47340.2019.8780035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本研究涉及心脏植入式电子装置(CIEDs)的电磁兼容性这一跨学科课题,用于心脏传导系统缺陷患者。本文就心脏刺激装置电极上检测到的电磁干扰问题进行了探讨。干扰信号的检测取决于与电极选择、器件放置、配置和编程有关的许多方面。本研究的目的是分析在干扰场的外部源存在下起搏器的响应。我们指出其相互作用的可能风险,并讨论可能影响起搏器对EMI敏感性的机制。最后,我们给出了心脏刺激系统暴露于低频时变场的一个真实案例和实验。本届会议的重点放在物理和技术方面,但它也与该问题的医疗部分有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices
The study deals with the interdisciplinary topic of the electromagnetic compatibility of the cardiac implantable electronic devices (CIEDs) that are used in patients with a defect of the heart conduction system. This article points on the issues of electromagnetic interference (EMI) detected on electrodes of cardiostimulation device. The detection of disturbance signals depends on many aspects related to electrode choice, device placement, it's configuration and programming. The aim of the study is the analysis of the pacemaker response in the presence of an external source of the disturbance fields. We point to possible risks of its interaction and discuss the mechanisms that can influence the pacemaker sensitivity to EMI. Finally, we present one real case and an experiment of the exposure of the cardiostimulation system to a low-frequency time-varying field. The emphasis of this session is put on physical and technical aspects, but it is also related to the medical part of the issue.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信