Haixin Huang, A. Poblaguev, D. Steski, K. Yip, A. Zelenski
{"title":"具有AGS P-carbon CNI偏振计操作经验","authors":"Haixin Huang, A. Poblaguev, D. Steski, K. Yip, A. Zelenski","doi":"10.22323/1.324.0023","DOIUrl":null,"url":null,"abstract":"The p-carbon polarimeter working in the dp/p Coulomb Nuclear Interference (CNI) region has \nbeen used in the Brookhaven Alternating Gradient Synchrotron (AGS ) for many years. It has \ngone though several upgrades to improve its performance. With targets sweeping through beam \nvertically and horizontally, the polarimeter can provide polarization profile information. To preserve \npolarization, a pair of horizontal tune jump quads have been used to overcome horizontal \nintrinsic resonances. Recently, the polarization measurement on the energy ramp has been used \nto decide the beam energy as function of time on the ramp. This paper summarize the recent \noperation experience of AGS p-carbon CNI polarimeter.","PeriodicalId":166894,"journal":{"name":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"AGS P-carbon CNI polarimeter Operation Experience\",\"authors\":\"Haixin Huang, A. Poblaguev, D. Steski, K. Yip, A. Zelenski\",\"doi\":\"10.22323/1.324.0023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The p-carbon polarimeter working in the dp/p Coulomb Nuclear Interference (CNI) region has \\nbeen used in the Brookhaven Alternating Gradient Synchrotron (AGS ) for many years. It has \\ngone though several upgrades to improve its performance. With targets sweeping through beam \\nvertically and horizontally, the polarimeter can provide polarization profile information. To preserve \\npolarization, a pair of horizontal tune jump quads have been used to overcome horizontal \\nintrinsic resonances. Recently, the polarization measurement on the energy ramp has been used \\nto decide the beam energy as function of time on the ramp. This paper summarize the recent \\noperation experience of AGS p-carbon CNI polarimeter.\",\"PeriodicalId\":166894,\"journal\":{\"name\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22323/1.324.0023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.324.0023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The p-carbon polarimeter working in the dp/p Coulomb Nuclear Interference (CNI) region has
been used in the Brookhaven Alternating Gradient Synchrotron (AGS ) for many years. It has
gone though several upgrades to improve its performance. With targets sweeping through beam
vertically and horizontally, the polarimeter can provide polarization profile information. To preserve
polarization, a pair of horizontal tune jump quads have been used to overcome horizontal
intrinsic resonances. Recently, the polarization measurement on the energy ramp has been used
to decide the beam energy as function of time on the ramp. This paper summarize the recent
operation experience of AGS p-carbon CNI polarimeter.