具有AGS P-carbon CNI偏振计操作经验

Haixin Huang, A. Poblaguev, D. Steski, K. Yip, A. Zelenski
{"title":"具有AGS P-carbon CNI偏振计操作经验","authors":"Haixin Huang, A. Poblaguev, D. Steski, K. Yip, A. Zelenski","doi":"10.22323/1.324.0023","DOIUrl":null,"url":null,"abstract":"The p-carbon polarimeter working in the dp/p Coulomb Nuclear Interference (CNI) region has \nbeen used in the Brookhaven Alternating Gradient Synchrotron (AGS ) for many years. It has \ngone though several upgrades to improve its performance. With targets sweeping through beam \nvertically and horizontally, the polarimeter can provide polarization profile information. To preserve \npolarization, a pair of horizontal tune jump quads have been used to overcome horizontal \nintrinsic resonances. Recently, the polarization measurement on the energy ramp has been used \nto decide the beam energy as function of time on the ramp. This paper summarize the recent \noperation experience of AGS p-carbon CNI polarimeter.","PeriodicalId":166894,"journal":{"name":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"AGS P-carbon CNI polarimeter Operation Experience\",\"authors\":\"Haixin Huang, A. Poblaguev, D. Steski, K. Yip, A. Zelenski\",\"doi\":\"10.22323/1.324.0023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The p-carbon polarimeter working in the dp/p Coulomb Nuclear Interference (CNI) region has \\nbeen used in the Brookhaven Alternating Gradient Synchrotron (AGS ) for many years. It has \\ngone though several upgrades to improve its performance. With targets sweeping through beam \\nvertically and horizontally, the polarimeter can provide polarization profile information. To preserve \\npolarization, a pair of horizontal tune jump quads have been used to overcome horizontal \\nintrinsic resonances. Recently, the polarization measurement on the energy ramp has been used \\nto decide the beam energy as function of time on the ramp. This paper summarize the recent \\noperation experience of AGS p-carbon CNI polarimeter.\",\"PeriodicalId\":166894,\"journal\":{\"name\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22323/1.324.0023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.324.0023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在布鲁克海文交变梯度同步加速器(AGS)中,工作于dp/p库仑核干涉(CNI)区的p-碳偏振计已使用多年。为了提高性能,它已经进行了几次升级。当目标垂直和水平扫过光束时,偏振计可以提供偏振剖面信息。为了保持极化,一对水平调谐跳变四元被用来克服水平固有共振。近年来,利用能量坡道上的偏振测量来确定光束能量随坡道上时间的函数。本文总结了近年来AGS p-碳CNI偏振仪的运行经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
AGS P-carbon CNI polarimeter Operation Experience
The p-carbon polarimeter working in the dp/p Coulomb Nuclear Interference (CNI) region has been used in the Brookhaven Alternating Gradient Synchrotron (AGS ) for many years. It has gone though several upgrades to improve its performance. With targets sweeping through beam vertically and horizontally, the polarimeter can provide polarization profile information. To preserve polarization, a pair of horizontal tune jump quads have been used to overcome horizontal intrinsic resonances. Recently, the polarization measurement on the energy ramp has been used to decide the beam energy as function of time on the ramp. This paper summarize the recent operation experience of AGS p-carbon CNI polarimeter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信