Meng Huang, C. Tse, Siu-Chung Wong, X. Ruan, C. Wan
{"title":"非理想电网三相电压源变换器的相互作用分岔现象","authors":"Meng Huang, C. Tse, Siu-Chung Wong, X. Ruan, C. Wan","doi":"10.1109/IECON.2013.6700536","DOIUrl":null,"url":null,"abstract":"Three-phase voltage source converters are commonly used to convert ac power from a three-phase grid to a regulated dc voltage with controlled unity input power factor. However, the non-ideal power grid may drive the converter to enter a low-frequency instability region. As a result of the emergence of low-frequency oscillation, the stability boundary leading to a catastrophic bifurcation shrinks dramatically. Simulation results show the interaction of the low-frequency oscillation and the catastrophic bifurcation. Analytical calculations based on harmonic balance are adopted to show how the stability margin is affected.","PeriodicalId":237327,"journal":{"name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Interacting bifurcation phenomenon in three-phase voltage source converter connected to non-ideal power grid\",\"authors\":\"Meng Huang, C. Tse, Siu-Chung Wong, X. Ruan, C. Wan\",\"doi\":\"10.1109/IECON.2013.6700536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three-phase voltage source converters are commonly used to convert ac power from a three-phase grid to a regulated dc voltage with controlled unity input power factor. However, the non-ideal power grid may drive the converter to enter a low-frequency instability region. As a result of the emergence of low-frequency oscillation, the stability boundary leading to a catastrophic bifurcation shrinks dramatically. Simulation results show the interaction of the low-frequency oscillation and the catastrophic bifurcation. Analytical calculations based on harmonic balance are adopted to show how the stability margin is affected.\",\"PeriodicalId\":237327,\"journal\":{\"name\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2013.6700536\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2013.6700536","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Interacting bifurcation phenomenon in three-phase voltage source converter connected to non-ideal power grid
Three-phase voltage source converters are commonly used to convert ac power from a three-phase grid to a regulated dc voltage with controlled unity input power factor. However, the non-ideal power grid may drive the converter to enter a low-frequency instability region. As a result of the emergence of low-frequency oscillation, the stability boundary leading to a catastrophic bifurcation shrinks dramatically. Simulation results show the interaction of the low-frequency oscillation and the catastrophic bifurcation. Analytical calculations based on harmonic balance are adopted to show how the stability margin is affected.