{"title":"岩棉基板电特性的阻抗测量系统","authors":"B. Iliev, G. Meijer","doi":"10.1109/SFICON.2004.1287127","DOIUrl":null,"url":null,"abstract":"An interface system for measuring rockwool water-content and water conductivity is presented. It is intended for measuring impedances that can be modeled as a parallel combination of a capacitance C/sub p/ and a resistance R/sub p/. In the particular application, the capacitance varies from 1 pF to 100 pF and the resistance can be in the range from few tens of ohms up to 5 k/spl Omega/ The measurements are conducted with a sinusoidal signal having a frequency of 20 MHz. At this frequency the full-scale error for C/sub p/ doesn't exceed 3,5% for a 100 pF range. The full-scale error for the measured R/sub p/ remains below 3,7% for a full-scale value of 5 k/spl Omega/ with the presented measurement principle resolution better than 0,2% can be achieved for both measured components.","PeriodicalId":381233,"journal":{"name":"ISA/IEEE Sensors for Industry Conference, 2004. Proceedings the","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"An impedance-measurement system for electrical characterization of rockwool substrates\",\"authors\":\"B. Iliev, G. Meijer\",\"doi\":\"10.1109/SFICON.2004.1287127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An interface system for measuring rockwool water-content and water conductivity is presented. It is intended for measuring impedances that can be modeled as a parallel combination of a capacitance C/sub p/ and a resistance R/sub p/. In the particular application, the capacitance varies from 1 pF to 100 pF and the resistance can be in the range from few tens of ohms up to 5 k/spl Omega/ The measurements are conducted with a sinusoidal signal having a frequency of 20 MHz. At this frequency the full-scale error for C/sub p/ doesn't exceed 3,5% for a 100 pF range. The full-scale error for the measured R/sub p/ remains below 3,7% for a full-scale value of 5 k/spl Omega/ with the presented measurement principle resolution better than 0,2% can be achieved for both measured components.\",\"PeriodicalId\":381233,\"journal\":{\"name\":\"ISA/IEEE Sensors for Industry Conference, 2004. Proceedings the\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISA/IEEE Sensors for Industry Conference, 2004. Proceedings the\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SFICON.2004.1287127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISA/IEEE Sensors for Industry Conference, 2004. Proceedings the","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SFICON.2004.1287127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An impedance-measurement system for electrical characterization of rockwool substrates
An interface system for measuring rockwool water-content and water conductivity is presented. It is intended for measuring impedances that can be modeled as a parallel combination of a capacitance C/sub p/ and a resistance R/sub p/. In the particular application, the capacitance varies from 1 pF to 100 pF and the resistance can be in the range from few tens of ohms up to 5 k/spl Omega/ The measurements are conducted with a sinusoidal signal having a frequency of 20 MHz. At this frequency the full-scale error for C/sub p/ doesn't exceed 3,5% for a 100 pF range. The full-scale error for the measured R/sub p/ remains below 3,7% for a full-scale value of 5 k/spl Omega/ with the presented measurement principle resolution better than 0,2% can be achieved for both measured components.