提高IGBT变换器效率和瞬态响应的技术

R. Turner, S. Walton, R. Duke
{"title":"提高IGBT变换器效率和瞬态响应的技术","authors":"R. Turner, S. Walton, R. Duke","doi":"10.1109/EPEPEMC.2008.4635320","DOIUrl":null,"url":null,"abstract":"For medium to large power converters (1 kW to 100 MW) the switching frequency is limited to ensure acceptable losses at the cost of converter performance (bandwidth). A technique is presented that dynamically changes the switching frequency to maintain a low average switching frequency but for transient events shorter than the thermal time constant of the device, the switching frequency and bandwidth are increased. Relationships between the switching frequency and bandwidth are developed, and a method for determining when and how to change bandwidths is introduced. The technique is shown to give improvements in THD compared to a fixed frequency system of the same average switching frequency (same losses) in a harmonic filter application.","PeriodicalId":149421,"journal":{"name":"2008 13th International Power Electronics and Motion Control Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Technique to improve IGBT converter efficiency and transient response\",\"authors\":\"R. Turner, S. Walton, R. Duke\",\"doi\":\"10.1109/EPEPEMC.2008.4635320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For medium to large power converters (1 kW to 100 MW) the switching frequency is limited to ensure acceptable losses at the cost of converter performance (bandwidth). A technique is presented that dynamically changes the switching frequency to maintain a low average switching frequency but for transient events shorter than the thermal time constant of the device, the switching frequency and bandwidth are increased. Relationships between the switching frequency and bandwidth are developed, and a method for determining when and how to change bandwidths is introduced. The technique is shown to give improvements in THD compared to a fixed frequency system of the same average switching frequency (same losses) in a harmonic filter application.\",\"PeriodicalId\":149421,\"journal\":{\"name\":\"2008 13th International Power Electronics and Motion Control Conference\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 13th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEPEMC.2008.4635320\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 13th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPEMC.2008.4635320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

对于中大型功率转换器(1kw到100mw),开关频率是有限的,以确保转换器性能(带宽)为代价的可接受的损失。提出了一种动态改变开关频率以保持较低的平均开关频率的技术,但对于短于器件热时间常数的瞬态事件,开关频率和带宽会增加。研究了开关频率与带宽之间的关系,并介绍了一种确定何时以及如何改变带宽的方法。与谐波滤波器应用中具有相同平均开关频率(相同损耗)的固定频率系统相比,该技术可以改善THD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Technique to improve IGBT converter efficiency and transient response
For medium to large power converters (1 kW to 100 MW) the switching frequency is limited to ensure acceptable losses at the cost of converter performance (bandwidth). A technique is presented that dynamically changes the switching frequency to maintain a low average switching frequency but for transient events shorter than the thermal time constant of the device, the switching frequency and bandwidth are increased. Relationships between the switching frequency and bandwidth are developed, and a method for determining when and how to change bandwidths is introduced. The technique is shown to give improvements in THD compared to a fixed frequency system of the same average switching frequency (same losses) in a harmonic filter application.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信