静态倒塌分析中临界切割组的确定

B. Raczkowski, P. Sauer
{"title":"静态倒塌分析中临界切割组的确定","authors":"B. Raczkowski, P. Sauer","doi":"10.1109/IREP.2007.4410565","DOIUrl":null,"url":null,"abstract":"This paper deals with static transfer stability limits (STSLs) of network branches, cutsets of network branches, and their relation to power flow Jacobian singularity. A minimal cutset is a grouping of system branches that -if removed from the system -separates the seller and buyer for a given transaction into two separate subsystems (islands) of the original network while containing no unnecessary branches in the grouping. Originally, it was proposed to define a critical cutset as a minimal cutset of system branches that exactly reaches its own cutset STSL (CSTSL) at the instant of power flow Jacobian singularity. However, it is shown that line inductive losses can reveal more information. A critical cutset is defined as the transfer loss stability limit (Critical Cut TLSL) as the point of system collapse. This paper proposes a conjecture that at least one minimal cutset in a power system is the critical cutset for a given transfer. Multiple power system models are analyzed to experimentally support the conjecture.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Identification of Critical Cutsets for Static Collapse Analysis\",\"authors\":\"B. Raczkowski, P. Sauer\",\"doi\":\"10.1109/IREP.2007.4410565\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with static transfer stability limits (STSLs) of network branches, cutsets of network branches, and their relation to power flow Jacobian singularity. A minimal cutset is a grouping of system branches that -if removed from the system -separates the seller and buyer for a given transaction into two separate subsystems (islands) of the original network while containing no unnecessary branches in the grouping. Originally, it was proposed to define a critical cutset as a minimal cutset of system branches that exactly reaches its own cutset STSL (CSTSL) at the instant of power flow Jacobian singularity. However, it is shown that line inductive losses can reveal more information. A critical cutset is defined as the transfer loss stability limit (Critical Cut TLSL) as the point of system collapse. This paper proposes a conjecture that at least one minimal cutset in a power system is the critical cutset for a given transfer. Multiple power system models are analyzed to experimentally support the conjecture.\",\"PeriodicalId\":214545,\"journal\":{\"name\":\"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IREP.2007.4410565\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREP.2007.4410565","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

研究了网络支路的静态传输稳定极限、支路的割集及其与潮流雅可比奇异性的关系。最小割集是一组系统分支,如果从系统中移除,它将给定交易的卖方和买方分离为原始网络的两个独立子系统(岛屿),同时在组中不包含不必要的分支。最初,提出将临界割集定义为在潮流雅可比奇异时刻恰好达到其自身割集STSL (CSTSL)的系统分支的最小割集。然而,线路电感损耗可以揭示更多的信息。临界割集定义为系统崩溃点的传输损失稳定极限(critical Cut TLSL)。本文提出了电力系统中至少有一个最小割集是给定传输的临界割集的猜想。对多个电力系统模型进行了实验分析,以支持这一猜想。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Identification of Critical Cutsets for Static Collapse Analysis
This paper deals with static transfer stability limits (STSLs) of network branches, cutsets of network branches, and their relation to power flow Jacobian singularity. A minimal cutset is a grouping of system branches that -if removed from the system -separates the seller and buyer for a given transaction into two separate subsystems (islands) of the original network while containing no unnecessary branches in the grouping. Originally, it was proposed to define a critical cutset as a minimal cutset of system branches that exactly reaches its own cutset STSL (CSTSL) at the instant of power flow Jacobian singularity. However, it is shown that line inductive losses can reveal more information. A critical cutset is defined as the transfer loss stability limit (Critical Cut TLSL) as the point of system collapse. This paper proposes a conjecture that at least one minimal cutset in a power system is the critical cutset for a given transfer. Multiple power system models are analyzed to experimentally support the conjecture.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信