通过监测浮充电流评估铅酸蓄电池的充电状态

K. D. Floyd, Z. Noworolski, J. M. Noworolski, W. Sokolski
{"title":"通过监测浮充电流评估铅酸蓄电池的充电状态","authors":"K. D. Floyd, Z. Noworolski, J. M. Noworolski, W. Sokolski","doi":"10.1109/INTLEC.1994.396590","DOIUrl":null,"url":null,"abstract":"In 1988, one user of flooded Pb-acid secondary batteries in a nuclear power plant began to measure float current in addition to specific gravity readings. A total of 780 cells were monitored. The results of this experience are summarized in this paper. A review of some of the electrochemistry involved is also presented. The analysis of the collected data has led to the conclusion that float current monitoring is preferred over specific gravity readings for assessing the state of charge of a Pb-acid battery. Now the problem turns to the availability of cost-effective, accurate provisions for measuring float current. The last part of this paper presents a test instrument design specifically for taking float current readings.<<ETX>>","PeriodicalId":123164,"journal":{"name":"Proceedings of Intelec 94","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Assessment of lead-acid battery state of charge by monitoring float charging current\",\"authors\":\"K. D. Floyd, Z. Noworolski, J. M. Noworolski, W. Sokolski\",\"doi\":\"10.1109/INTLEC.1994.396590\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In 1988, one user of flooded Pb-acid secondary batteries in a nuclear power plant began to measure float current in addition to specific gravity readings. A total of 780 cells were monitored. The results of this experience are summarized in this paper. A review of some of the electrochemistry involved is also presented. The analysis of the collected data has led to the conclusion that float current monitoring is preferred over specific gravity readings for assessing the state of charge of a Pb-acid battery. Now the problem turns to the availability of cost-effective, accurate provisions for measuring float current. The last part of this paper presents a test instrument design specifically for taking float current readings.<<ETX>>\",\"PeriodicalId\":123164,\"journal\":{\"name\":\"Proceedings of Intelec 94\",\"volume\":\"94 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Intelec 94\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1994.396590\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Intelec 94","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1994.396590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

1988年,核电厂中一个铅酸二次电池的用户除了测量比重外,还开始测量浮子电流。共监测780个细胞。本文对这一经验的结果进行了总结。对所涉及的一些电化学的回顾也被提出。对收集到的数据的分析得出结论,在评估铅酸电池的充电状态时,浮子电流监测比比重读数更可取。现在的问题变成了成本效益高、准确的浮子电流测量装置。本文的最后一部分介绍了一种专门用于测量浮子电流的测试仪器的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of lead-acid battery state of charge by monitoring float charging current
In 1988, one user of flooded Pb-acid secondary batteries in a nuclear power plant began to measure float current in addition to specific gravity readings. A total of 780 cells were monitored. The results of this experience are summarized in this paper. A review of some of the electrochemistry involved is also presented. The analysis of the collected data has led to the conclusion that float current monitoring is preferred over specific gravity readings for assessing the state of charge of a Pb-acid battery. Now the problem turns to the availability of cost-effective, accurate provisions for measuring float current. The last part of this paper presents a test instrument design specifically for taking float current readings.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信