{"title":"x射线发生器模拟器的设计","authors":"Akash Shinde, Swapnil G. Mali, Sreekumar Thekkuttu","doi":"10.1109/ICMACC54824.2022.10093314","DOIUrl":null,"url":null,"abstract":"X-ray machine systems are used to acquire X-ray images of internal human body parts. A C-arm is a type of X-ray machine system used to produce X-ray images of desired body parts. The creation of X-rays is essential to the development of X-ray images. An X-ray generator built within the C-arm system produces the X-rays. The Master Controller is the brain of C-arm systems, which monitors and controls all the components of the C-arm system. Communication between the Master Controller and the X-ray generator is required in order to regulate the various functionalities of the X-ray generator. Using an actual X-ray generator to test the C-arm system's performance can be expensive and time-consuming. Thus, it is necessary to create a simulator that may take the role of an X-ray generator. In this research, a novel method for creating an X-ray generator simulator that uses an Arduino board in place of the X-ray generator is discussed. The Arduino board is programmed to perform like an X-ray generator, and communication between the Arduino board and Master Controller is obtained to simulate the functionalities of an X-ray generator.","PeriodicalId":293018,"journal":{"name":"2022 International Conference on Recent Trends in Microelectronics, Automation, Computing and Communications Systems (ICMACC)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of X-ray Generator Simulator\",\"authors\":\"Akash Shinde, Swapnil G. Mali, Sreekumar Thekkuttu\",\"doi\":\"10.1109/ICMACC54824.2022.10093314\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"X-ray machine systems are used to acquire X-ray images of internal human body parts. A C-arm is a type of X-ray machine system used to produce X-ray images of desired body parts. The creation of X-rays is essential to the development of X-ray images. An X-ray generator built within the C-arm system produces the X-rays. The Master Controller is the brain of C-arm systems, which monitors and controls all the components of the C-arm system. Communication between the Master Controller and the X-ray generator is required in order to regulate the various functionalities of the X-ray generator. Using an actual X-ray generator to test the C-arm system's performance can be expensive and time-consuming. Thus, it is necessary to create a simulator that may take the role of an X-ray generator. In this research, a novel method for creating an X-ray generator simulator that uses an Arduino board in place of the X-ray generator is discussed. The Arduino board is programmed to perform like an X-ray generator, and communication between the Arduino board and Master Controller is obtained to simulate the functionalities of an X-ray generator.\",\"PeriodicalId\":293018,\"journal\":{\"name\":\"2022 International Conference on Recent Trends in Microelectronics, Automation, Computing and Communications Systems (ICMACC)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Recent Trends in Microelectronics, Automation, Computing and Communications Systems (ICMACC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMACC54824.2022.10093314\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Recent Trends in Microelectronics, Automation, Computing and Communications Systems (ICMACC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMACC54824.2022.10093314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
X-ray machine systems are used to acquire X-ray images of internal human body parts. A C-arm is a type of X-ray machine system used to produce X-ray images of desired body parts. The creation of X-rays is essential to the development of X-ray images. An X-ray generator built within the C-arm system produces the X-rays. The Master Controller is the brain of C-arm systems, which monitors and controls all the components of the C-arm system. Communication between the Master Controller and the X-ray generator is required in order to regulate the various functionalities of the X-ray generator. Using an actual X-ray generator to test the C-arm system's performance can be expensive and time-consuming. Thus, it is necessary to create a simulator that may take the role of an X-ray generator. In this research, a novel method for creating an X-ray generator simulator that uses an Arduino board in place of the X-ray generator is discussed. The Arduino board is programmed to perform like an X-ray generator, and communication between the Arduino board and Master Controller is obtained to simulate the functionalities of an X-ray generator.