{"title":"用单分子热透镜显微镜检测石英芯片上的纳米通道","authors":"K. Matsumoto, T. Kawakami, M. Nakao, Y. Hatamura, T. Kitamori, T. Sawada","doi":"10.1109/MEMSYS.1998.659741","DOIUrl":null,"url":null,"abstract":"To execute chemical experiments with less sample volume, shorter experiment time and higher measurement resolution, the authors are developing a quartz-chip laboratory with a thermal lens microscope. However, turbulence of fluid flow causes double-count measurement error of microparticles. To increase preciseness of the measurement, a narrow lamina-flow channels called \"nano-channel\" is employed. Nano-channels of 50 and 900 nm width, flat-structured ball mixer and bubble pump/valve were designed and fabricated on a quartz substrate to estimate their feasibilities.","PeriodicalId":340972,"journal":{"name":"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Nano-channel on quartz-chip laboratory using single molecular detectable thermal lens microscope\",\"authors\":\"K. Matsumoto, T. Kawakami, M. Nakao, Y. Hatamura, T. Kitamori, T. Sawada\",\"doi\":\"10.1109/MEMSYS.1998.659741\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To execute chemical experiments with less sample volume, shorter experiment time and higher measurement resolution, the authors are developing a quartz-chip laboratory with a thermal lens microscope. However, turbulence of fluid flow causes double-count measurement error of microparticles. To increase preciseness of the measurement, a narrow lamina-flow channels called \\\"nano-channel\\\" is employed. Nano-channels of 50 and 900 nm width, flat-structured ball mixer and bubble pump/valve were designed and fabricated on a quartz substrate to estimate their feasibilities.\",\"PeriodicalId\":340972,\"journal\":{\"name\":\"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.1998.659741\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.1998.659741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

为了实现更小样本量、更短实验时间和更高测量分辨率的化学实验,作者正在开发一种带有热透镜显微镜的石英芯片实验室。然而,流体流动的湍流性会导致微粒的重复计数测量误差。为了提高测量的准确性,采用了一种称为“纳米通道”的窄层流通道。在石英衬底上设计并制作了50 nm和900 nm宽的纳米通道、扁平结构的球混合器和气泡泵/阀,以评估其可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Nano-channel on quartz-chip laboratory using single molecular detectable thermal lens microscope
To execute chemical experiments with less sample volume, shorter experiment time and higher measurement resolution, the authors are developing a quartz-chip laboratory with a thermal lens microscope. However, turbulence of fluid flow causes double-count measurement error of microparticles. To increase preciseness of the measurement, a narrow lamina-flow channels called "nano-channel" is employed. Nano-channels of 50 and 900 nm width, flat-structured ball mixer and bubble pump/valve were designed and fabricated on a quartz substrate to estimate their feasibilities.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信