{"title":"容错VSI中直流链路电压摆动与负载电流不平衡。概述与薪酬策略","authors":"V. Boscaino, A. D. Di Tommaso, F. Genduso, R. Miceli","doi":"10.1109/AEIT.2015.7415268","DOIUrl":null,"url":null,"abstract":"The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating preventive or repressive strategies in different application scenarios. These strategies can operate both in open and closed loop control. The paper highlights their advantages, drawbacks and analyzes their different behavior.","PeriodicalId":368119,"journal":{"name":"2015 AEIT International Annual Conference (AEIT)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies\",\"authors\":\"V. Boscaino, A. D. Di Tommaso, F. Genduso, R. Miceli\",\"doi\":\"10.1109/AEIT.2015.7415268\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating preventive or repressive strategies in different application scenarios. These strategies can operate both in open and closed loop control. The paper highlights their advantages, drawbacks and analyzes their different behavior.\",\"PeriodicalId\":368119,\"journal\":{\"name\":\"2015 AEIT International Annual Conference (AEIT)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 AEIT International Annual Conference (AEIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEIT.2015.7415268\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 AEIT International Annual Conference (AEIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEIT.2015.7415268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文的主题是讨论三相容错逆变器的性能,特别关注逆变器重新配置后由于直流链路电压波动而引起的电流不平衡被低估的方面。电容器电压不平衡不仅影响逆变器的平均输出电压,而且影响逆变器的性能。实际上,逆变器的性能取决于波动直流电压分量,而不是平均直流电压。在简要分析了容错配置引起的电压波动现象及其对负载电流不平衡的影响后,作者考虑了在不同应用场景下不同的补偿预防或抑制策略。这些策略可以在开环和闭环控制中运行。本文突出了它们的优缺点,并分析了它们的不同行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies
The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating preventive or repressive strategies in different application scenarios. These strategies can operate both in open and closed loop control. The paper highlights their advantages, drawbacks and analyzes their different behavior.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信