具有灵敏度控制性能限制的机电系统结构设计

J. Shirao, J. Imai, M. Konishi
{"title":"具有灵敏度控制性能限制的机电系统结构设计","authors":"J. Shirao, J. Imai, M. Konishi","doi":"10.1109/SICE.2006.315647","DOIUrl":null,"url":null,"abstract":"Use of control systems performance limitation is made to design mechanical structure of a counterbalance in a one-link arm that swings vertically forced by a direct-drive motor. It is well known that, by Bode's integral, sensitivity performance of the control systems is essentially limited and that the bandwidth of the open loop transfer function causes a kind of waterbed effects. The performance bounds are proved to be affected significantly by the poles location, the inertia moment, as well as the dominant characteristic frequency of the plant. Therefore it is claimed that a sensitivity specification provides useful designing conditions in terms of a plant, and that the plant with no unstable poles, a low inertia moment and a low characteristic frequency is generally desirable to meet it. The conditions are straightforwardly recited into ones for physical parameters such as mass, length and angle of the counterbalance. Effectiveness of the proposed approach for structure design of a counterbalance is illustrated by a standard controller synthesis and nonlinear numerical simulation","PeriodicalId":309260,"journal":{"name":"2006 SICE-ICASE International Joint Conference","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Structure design with sensitivity control performance limitation for electromechanical systems\",\"authors\":\"J. Shirao, J. Imai, M. Konishi\",\"doi\":\"10.1109/SICE.2006.315647\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Use of control systems performance limitation is made to design mechanical structure of a counterbalance in a one-link arm that swings vertically forced by a direct-drive motor. It is well known that, by Bode's integral, sensitivity performance of the control systems is essentially limited and that the bandwidth of the open loop transfer function causes a kind of waterbed effects. The performance bounds are proved to be affected significantly by the poles location, the inertia moment, as well as the dominant characteristic frequency of the plant. Therefore it is claimed that a sensitivity specification provides useful designing conditions in terms of a plant, and that the plant with no unstable poles, a low inertia moment and a low characteristic frequency is generally desirable to meet it. The conditions are straightforwardly recited into ones for physical parameters such as mass, length and angle of the counterbalance. Effectiveness of the proposed approach for structure design of a counterbalance is illustrated by a standard controller synthesis and nonlinear numerical simulation\",\"PeriodicalId\":309260,\"journal\":{\"name\":\"2006 SICE-ICASE International Joint Conference\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 SICE-ICASE International Joint Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2006.315647\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 SICE-ICASE International Joint Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2006.315647","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

利用控制系统的性能限制,设计了在直驱电机驱动下垂直摆动的单连杆臂平衡器的机械结构。众所周知,通过波德积分,控制系统的灵敏度性能本质上是有限的,并且开环传递函数的带宽会引起一种水床效应。结果表明,极点位置、转动惯量以及系统的主导特性频率对系统的性能边界有显著影响。因此,我们认为灵敏度规格提供了有用的设计条件,而无不稳定极点、低惯性矩和低特征频率的装置通常是理想的。这些条件被直接背诵为物理参数,如质量,长度和角度的平衡。通过标准控制器综合和非线性数值仿真验证了该方法在平衡器结构设计中的有效性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Structure design with sensitivity control performance limitation for electromechanical systems
Use of control systems performance limitation is made to design mechanical structure of a counterbalance in a one-link arm that swings vertically forced by a direct-drive motor. It is well known that, by Bode's integral, sensitivity performance of the control systems is essentially limited and that the bandwidth of the open loop transfer function causes a kind of waterbed effects. The performance bounds are proved to be affected significantly by the poles location, the inertia moment, as well as the dominant characteristic frequency of the plant. Therefore it is claimed that a sensitivity specification provides useful designing conditions in terms of a plant, and that the plant with no unstable poles, a low inertia moment and a low characteristic frequency is generally desirable to meet it. The conditions are straightforwardly recited into ones for physical parameters such as mass, length and angle of the counterbalance. Effectiveness of the proposed approach for structure design of a counterbalance is illustrated by a standard controller synthesis and nonlinear numerical simulation
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信