用最新的点击分析仪测量不连续干扰的陷阱

Mario Monti, Elena Puri, Massimo Monti
{"title":"用最新的点击分析仪测量不连续干扰的陷阱","authors":"Mario Monti, Elena Puri, Massimo Monti","doi":"10.1109/ISEMC.2016.7571563","DOIUrl":null,"url":null,"abstract":"The recent advancing in click analyser technology aims at reducing costs and time required to perform a full CISPR 14-1 compliant click measurement. The two relevant approaches to achieve costs and time reductions are, respectively, the use of Fast Fourier Transform (FFT) EMI receivers and performing the threshold calculation and actual measurement in a single run (single-run systems). However, there are some critical aspects related to these approaches. (i) The reduced dynamic range, emphasized in FFT receivers and single-run systems, can lead to underestimated measurements. (ii) The partial consideration of the disturbance (i.e., only its amplitude but not its shape in time) can make single-run systems susceptible to an erroneous calculation of clicks. Still, both approaches can be pursued with certain precautions: a specific circuitry to notify an overload condition of click analysers in general and the recording of both IF and quasi-peak channels in single-run systems. By thoroughly discussing the two issues and the related proposed precautions, we undermine popular claims of click analyser manufacturers and reconsider common beliefs about click analysers. We report on important technical aspects and scarcely known details, supporting our claims with simple lab tests and examples.","PeriodicalId":326016,"journal":{"name":"2016 IEEE International Symposium on Electromagnetic Compatibility (EMC)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Pitfalls in measuring discontinuous disturbances with latest click analysers\",\"authors\":\"Mario Monti, Elena Puri, Massimo Monti\",\"doi\":\"10.1109/ISEMC.2016.7571563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The recent advancing in click analyser technology aims at reducing costs and time required to perform a full CISPR 14-1 compliant click measurement. The two relevant approaches to achieve costs and time reductions are, respectively, the use of Fast Fourier Transform (FFT) EMI receivers and performing the threshold calculation and actual measurement in a single run (single-run systems). However, there are some critical aspects related to these approaches. (i) The reduced dynamic range, emphasized in FFT receivers and single-run systems, can lead to underestimated measurements. (ii) The partial consideration of the disturbance (i.e., only its amplitude but not its shape in time) can make single-run systems susceptible to an erroneous calculation of clicks. Still, both approaches can be pursued with certain precautions: a specific circuitry to notify an overload condition of click analysers in general and the recording of both IF and quasi-peak channels in single-run systems. By thoroughly discussing the two issues and the related proposed precautions, we undermine popular claims of click analyser manufacturers and reconsider common beliefs about click analysers. We report on important technical aspects and scarcely known details, supporting our claims with simple lab tests and examples.\",\"PeriodicalId\":326016,\"journal\":{\"name\":\"2016 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2016.7571563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Electromagnetic Compatibility (EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2016.7571563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

点击分析仪技术的最新进展旨在降低执行完整CISPR 14-1合规点击测量所需的成本和时间。实现成本和时间降低的两种相关方法分别是使用快速傅里叶变换(FFT) EMI接收器,以及在单次运行(单次运行系统)中执行阈值计算和实际测量。然而,与这些方法相关的一些关键方面。(i) FFT接收机和单次运行系统所强调的减小的动态范围可能导致低估的测量结果。(ii)对扰动的部分考虑(即只考虑扰动的幅度,而不考虑扰动的时间形状)可能使单次运行系统容易产生错误的咔嗒计算。尽管如此,这两种方法都可以通过一定的预防措施来实现:一个特定的电路来通知一般的点击分析仪的过载情况,以及在单次运行系统中记录中频和准峰值通道。通过深入讨论这两个问题和相关的预防措施,我们破坏了点击分析仪制造商的流行主张,并重新考虑了关于点击分析仪的普遍信念。我们报告重要的技术方面和鲜为人知的细节,用简单的实验室测试和例子来支持我们的主张。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pitfalls in measuring discontinuous disturbances with latest click analysers
The recent advancing in click analyser technology aims at reducing costs and time required to perform a full CISPR 14-1 compliant click measurement. The two relevant approaches to achieve costs and time reductions are, respectively, the use of Fast Fourier Transform (FFT) EMI receivers and performing the threshold calculation and actual measurement in a single run (single-run systems). However, there are some critical aspects related to these approaches. (i) The reduced dynamic range, emphasized in FFT receivers and single-run systems, can lead to underestimated measurements. (ii) The partial consideration of the disturbance (i.e., only its amplitude but not its shape in time) can make single-run systems susceptible to an erroneous calculation of clicks. Still, both approaches can be pursued with certain precautions: a specific circuitry to notify an overload condition of click analysers in general and the recording of both IF and quasi-peak channels in single-run systems. By thoroughly discussing the two issues and the related proposed precautions, we undermine popular claims of click analyser manufacturers and reconsider common beliefs about click analysers. We report on important technical aspects and scarcely known details, supporting our claims with simple lab tests and examples.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信