J. Bian, D. Ramey, R. J. Nelson, A. Edris
{"title":"统一潮流控制器的设备尺寸及约束研究","authors":"J. Bian, D. Ramey, R. J. Nelson, A. Edris","doi":"10.1109/TDC.1996.545956","DOIUrl":null,"url":null,"abstract":"This paper provides a quantitative measurement of the benefit that a unified power flow controller (UPFC) can provide to increase firm power transfer between two large power systems. Included is a complete model for a UPFC control system that contains bus voltage control by the shunt inverter, real power transfer between the shunt and series inverters, and real and reactive power control for the transmission line into which the series inverter is inserted. A significant part of the model is representation of dynamic limits that coordinate injected current limits for the shunt inverter, power transfer limits between inverters, voltage injection limits for the series inverter, current limits for the series inverter, and line voltage limits for the transmission line. This paper contains a simple system simulation to demonstrate the coordinated dynamic control and illustrate issues that system planning engineers must consider in defining applications for a UPFC.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"110","resultStr":"{\"title\":\"A study of equipment sizes and constraints for a unified power flow controller\",\"authors\":\"J. Bian, D. Ramey, R. J. Nelson, A. Edris\",\"doi\":\"10.1109/TDC.1996.545956\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper provides a quantitative measurement of the benefit that a unified power flow controller (UPFC) can provide to increase firm power transfer between two large power systems. Included is a complete model for a UPFC control system that contains bus voltage control by the shunt inverter, real power transfer between the shunt and series inverters, and real and reactive power control for the transmission line into which the series inverter is inserted. A significant part of the model is representation of dynamic limits that coordinate injected current limits for the shunt inverter, power transfer limits between inverters, voltage injection limits for the series inverter, current limits for the series inverter, and line voltage limits for the transmission line. This paper contains a simple system simulation to demonstrate the coordinated dynamic control and illustrate issues that system planning engineers must consider in defining applications for a UPFC.\",\"PeriodicalId\":105076,\"journal\":{\"name\":\"Proceedings of 1996 Transmission and Distribution Conference and Exposition\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"110\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1996 Transmission and Distribution Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC.1996.545956\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.1996.545956","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 110

摘要

本文提供了统一潮流控制器(UPFC)为增加两个大型电力系统之间的稳定电力传输所带来的效益的定量测量。包括UPFC控制系统的完整模型,其中包含由并联逆变器控制的母线电压,并联逆变器和串联逆变器之间的实际功率传输,以及串联逆变器插入的传输线的实际和无功功率控制。该模型的一个重要部分是动态限值的表示,它协调了并联逆变器的注入电流限值、逆变器之间的功率传输限值、串联逆变器的注入电压限值、串联逆变器的电流限值和传输线的线路电压限值。本文包含一个简单的系统仿真来演示协调动态控制,并说明系统规划工程师在定义UPFC应用时必须考虑的问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A study of equipment sizes and constraints for a unified power flow controller
This paper provides a quantitative measurement of the benefit that a unified power flow controller (UPFC) can provide to increase firm power transfer between two large power systems. Included is a complete model for a UPFC control system that contains bus voltage control by the shunt inverter, real power transfer between the shunt and series inverters, and real and reactive power control for the transmission line into which the series inverter is inserted. A significant part of the model is representation of dynamic limits that coordinate injected current limits for the shunt inverter, power transfer limits between inverters, voltage injection limits for the series inverter, current limits for the series inverter, and line voltage limits for the transmission line. This paper contains a simple system simulation to demonstrate the coordinated dynamic control and illustrate issues that system planning engineers must consider in defining applications for a UPFC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书