{"title":"利用混响和半消声室抗扰度试验测量变形传输线的感应功率","authors":"M. Obholz, D. Peier","doi":"10.1109/EMCZUR.2009.4783483","DOIUrl":null,"url":null,"abstract":"Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.","PeriodicalId":192851,"journal":{"name":"2009 20th International Zurich Symposium on Electromagnetic Compatibility","volume":"213 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Measurements of the Induced Power in a Shape Shifting Transmission Line According to Immunity Tests in Reverberation and Semi Anechoic Chamber\",\"authors\":\"M. Obholz, D. Peier\",\"doi\":\"10.1109/EMCZUR.2009.4783483\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.\",\"PeriodicalId\":192851,\"journal\":{\"name\":\"2009 20th International Zurich Symposium on Electromagnetic Compatibility\",\"volume\":\"213 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 20th International Zurich Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCZUR.2009.4783483\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 20th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2009.4783483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurements of the Induced Power in a Shape Shifting Transmission Line According to Immunity Tests in Reverberation and Semi Anechoic Chamber
Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.