{"title":"低频域故障检测观测器设计","authors":"Heng Wang, Guanghong Yang","doi":"10.1109/CCA.2007.4389360","DOIUrl":null,"url":null,"abstract":"This paper studies the H_/Hinfin fault detection problem in the low frequency domain with the aid of the recently developed generalized Kalman-Yakubovic-Popov (KYP) lemma, which gives an accurate characterization of the H_ index in the low frequency domain. The low frequency H_ index and another important performance index Hinfin norm are used to measure the low frequency fault and disturbance effects respectively, and an LMI-based method of designing fault detection observers is presented. An example of the VTOL aircraft is studied to illustrate the effectiveness of the proposed method.","PeriodicalId":176828,"journal":{"name":"2007 IEEE International Conference on Control Applications","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Fault Detection Observer Design in Low Frequency Domain\",\"authors\":\"Heng Wang, Guanghong Yang\",\"doi\":\"10.1109/CCA.2007.4389360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper studies the H_/Hinfin fault detection problem in the low frequency domain with the aid of the recently developed generalized Kalman-Yakubovic-Popov (KYP) lemma, which gives an accurate characterization of the H_ index in the low frequency domain. The low frequency H_ index and another important performance index Hinfin norm are used to measure the low frequency fault and disturbance effects respectively, and an LMI-based method of designing fault detection observers is presented. An example of the VTOL aircraft is studied to illustrate the effectiveness of the proposed method.\",\"PeriodicalId\":176828,\"journal\":{\"name\":\"2007 IEEE International Conference on Control Applications\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE International Conference on Control Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCA.2007.4389360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Conference on Control Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCA.2007.4389360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault Detection Observer Design in Low Frequency Domain
This paper studies the H_/Hinfin fault detection problem in the low frequency domain with the aid of the recently developed generalized Kalman-Yakubovic-Popov (KYP) lemma, which gives an accurate characterization of the H_ index in the low frequency domain. The low frequency H_ index and another important performance index Hinfin norm are used to measure the low frequency fault and disturbance effects respectively, and an LMI-based method of designing fault detection observers is presented. An example of the VTOL aircraft is studied to illustrate the effectiveness of the proposed method.