{"title":"静态无功补偿器的实验室实现","authors":"Jernej Cernelic, G. Štumberger","doi":"10.1109/CPE.2013.6601140","DOIUrl":null,"url":null,"abstract":"In a low voltage distribution network, wisely applied local reactive power generation can improve voltage profiles and reduce loses related with the energy transmission. This paper deals with the laboratory realization of a Static VAr compensator (STATCOM) suitable for adjustable local reactive power generation. In the case study, the basic design of a 10 kVA STATCOM is presented. The paper contains description of the discussed system, design of the LCL output filter, and determination of gains for the Voltage oriented control with PI controllers (VOC-PI). The comparison of measured and calculated responses shows a good agreement. The results presented in the paper show acceptable dynamic responses satisfactory power efficiency of the laboratory STATCOM realization.","PeriodicalId":128620,"journal":{"name":"2013 International Conference-Workshop Compatibility And Power Electronics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Laboratory realization of a Static VAr compensator\",\"authors\":\"Jernej Cernelic, G. Štumberger\",\"doi\":\"10.1109/CPE.2013.6601140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In a low voltage distribution network, wisely applied local reactive power generation can improve voltage profiles and reduce loses related with the energy transmission. This paper deals with the laboratory realization of a Static VAr compensator (STATCOM) suitable for adjustable local reactive power generation. In the case study, the basic design of a 10 kVA STATCOM is presented. The paper contains description of the discussed system, design of the LCL output filter, and determination of gains for the Voltage oriented control with PI controllers (VOC-PI). The comparison of measured and calculated responses shows a good agreement. The results presented in the paper show acceptable dynamic responses satisfactory power efficiency of the laboratory STATCOM realization.\",\"PeriodicalId\":128620,\"journal\":{\"name\":\"2013 International Conference-Workshop Compatibility And Power Electronics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Conference-Workshop Compatibility And Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE.2013.6601140\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference-Workshop Compatibility And Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2013.6601140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Laboratory realization of a Static VAr compensator
In a low voltage distribution network, wisely applied local reactive power generation can improve voltage profiles and reduce loses related with the energy transmission. This paper deals with the laboratory realization of a Static VAr compensator (STATCOM) suitable for adjustable local reactive power generation. In the case study, the basic design of a 10 kVA STATCOM is presented. The paper contains description of the discussed system, design of the LCL output filter, and determination of gains for the Voltage oriented control with PI controllers (VOC-PI). The comparison of measured and calculated responses shows a good agreement. The results presented in the paper show acceptable dynamic responses satisfactory power efficiency of the laboratory STATCOM realization.