{"title":"2019年印尼水上公开锦标赛自由泳运动员运动学分析","authors":"Billy Emir Rizkanto, Afif Rusdiawan","doi":"10.29407/js_unpgri.v7i2.15877","DOIUrl":null,"url":null,"abstract":"This study aims to determine the kinematics of the men's 50 and 100 meter freestyle swimming athletes. Research method uses quantitative descriptive with 50 meter swimmers and 100 meter freestyle men at the 2019 IOAC championship. Instrument used was a Sony Rx-10Mark IV camera placed in the highest stands at a distance of 25 m in a 50-meter pool. Video results analyzed using the Kinovea 0.8.27 software by calculating the SF,SV,SR, and SL. The results showed that the average number of a 50meter had an SF of 13.06,SV of 1.89 m.s-1,SR of 59.08 cycles.min-1, and SL of 1.92 m.cycle-1. The 100 meter number, the average SF value is 11.8 at a distance of 50-meter and 12.08 at 100 meter. In comparison, the SV average is 1.73 m.s-1 at a distance of 50 and 1.72 m.s-1 at a distance of 100-meter. SR the average is 46.35 cycles.min-1 distance of 50 meter and 50, 2 100 m distance. SL the average is 2.25 m.cycle-1 distance of 50-meter and 2.08 distance of 100-meter. Conclusion, are differences in kinematics of swimming between the men's 50 meter and 100 meter freestyle in SV and SR,while those in SF and SL tend to be the same.","PeriodicalId":353164,"journal":{"name":"Jurnal SPORTIF : Jurnal Penelitian Pembelajaran","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Kinematics analysis of freestyle swimming athletes at the 2019 Indonesia Open Aquatic Championship (IOAC)\",\"authors\":\"Billy Emir Rizkanto, Afif Rusdiawan\",\"doi\":\"10.29407/js_unpgri.v7i2.15877\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims to determine the kinematics of the men's 50 and 100 meter freestyle swimming athletes. Research method uses quantitative descriptive with 50 meter swimmers and 100 meter freestyle men at the 2019 IOAC championship. Instrument used was a Sony Rx-10Mark IV camera placed in the highest stands at a distance of 25 m in a 50-meter pool. Video results analyzed using the Kinovea 0.8.27 software by calculating the SF,SV,SR, and SL. The results showed that the average number of a 50meter had an SF of 13.06,SV of 1.89 m.s-1,SR of 59.08 cycles.min-1, and SL of 1.92 m.cycle-1. The 100 meter number, the average SF value is 11.8 at a distance of 50-meter and 12.08 at 100 meter. In comparison, the SV average is 1.73 m.s-1 at a distance of 50 and 1.72 m.s-1 at a distance of 100-meter. SR the average is 46.35 cycles.min-1 distance of 50 meter and 50, 2 100 m distance. SL the average is 2.25 m.cycle-1 distance of 50-meter and 2.08 distance of 100-meter. Conclusion, are differences in kinematics of swimming between the men's 50 meter and 100 meter freestyle in SV and SR,while those in SF and SL tend to be the same.\",\"PeriodicalId\":353164,\"journal\":{\"name\":\"Jurnal SPORTIF : Jurnal Penelitian Pembelajaran\",\"volume\":\"81 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal SPORTIF : Jurnal Penelitian Pembelajaran\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29407/js_unpgri.v7i2.15877\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal SPORTIF : Jurnal Penelitian Pembelajaran","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29407/js_unpgri.v7i2.15877","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
本研究旨在确定男子50米和100米自由泳运动员的运动学。研究方法采用定量描述的方法,对2019年iac锦标赛男子50米和100米自由泳进行了研究。使用的仪器是一台索尼Rx-10Mark IV相机,放置在距离50米游泳池25米的最高看台上。利用Kinovea 0.8.27软件对视频结果进行分析,计算SF、SV、SR和SL,结果表明,平均50米数的SF为13.06,SV为1.89 ms -1,SR为59.08 cycles。min-1,和SL 1.92 m.cycle-1。在100米距离上,50米距离的平均顺流线值为11.8,100米距离的平均顺流线值为12.08。相比之下,距离50米时的SV平均值为1.73 m.s-1,距离100米时为1.72 m.s-1。SR平均值为46.35个周期。Min-1距离有50米、50米、2米等距离。平均为2.25米,50米,100米,2.08米。结论:男子50米和100米自由泳的运动学在SV和SR中存在差异,而在SF和SL中则趋于一致。
Kinematics analysis of freestyle swimming athletes at the 2019 Indonesia Open Aquatic Championship (IOAC)
This study aims to determine the kinematics of the men's 50 and 100 meter freestyle swimming athletes. Research method uses quantitative descriptive with 50 meter swimmers and 100 meter freestyle men at the 2019 IOAC championship. Instrument used was a Sony Rx-10Mark IV camera placed in the highest stands at a distance of 25 m in a 50-meter pool. Video results analyzed using the Kinovea 0.8.27 software by calculating the SF,SV,SR, and SL. The results showed that the average number of a 50meter had an SF of 13.06,SV of 1.89 m.s-1,SR of 59.08 cycles.min-1, and SL of 1.92 m.cycle-1. The 100 meter number, the average SF value is 11.8 at a distance of 50-meter and 12.08 at 100 meter. In comparison, the SV average is 1.73 m.s-1 at a distance of 50 and 1.72 m.s-1 at a distance of 100-meter. SR the average is 46.35 cycles.min-1 distance of 50 meter and 50, 2 100 m distance. SL the average is 2.25 m.cycle-1 distance of 50-meter and 2.08 distance of 100-meter. Conclusion, are differences in kinematics of swimming between the men's 50 meter and 100 meter freestyle in SV and SR,while those in SF and SL tend to be the same.