M. Mannah, Michael Nahas, Abdel-Razzak Merheb, Ahmad Haddad
{"title":"小型住宅单元独立混合系统的有效性评估:黎巴嫩案例研究","authors":"M. Mannah, Michael Nahas, Abdel-Razzak Merheb, Ahmad Haddad","doi":"10.1109/imcet53404.2021.9665498","DOIUrl":null,"url":null,"abstract":"In this paper, a hybrid system based on solar and wind energy sources is designed, simulated and evaluated in terms of performance and economic interest. When there is a drop of power, fuel cells are used to manage the deficiency. The investigated system is situated in Lebanon and the sizing takes into account the surrounding conditions such as meteorological data and particularities of the Lebanese situation. The main objective is to optimize the design such as the PV, wind and FC system would fully supply a typical 5 kW residential unit in Lebanon without any need for backup. A cost study is carried out in order to evaluate the effectiveness of such solution and whether it is applicable or of interest.","PeriodicalId":181607,"journal":{"name":"2021 IEEE 3rd International Multidisciplinary Conference on Engineering Technology (IMCET)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Effectiveness of Standalone Hybrid Systems for Small Residential Units: Case Study Lebanon\",\"authors\":\"M. Mannah, Michael Nahas, Abdel-Razzak Merheb, Ahmad Haddad\",\"doi\":\"10.1109/imcet53404.2021.9665498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a hybrid system based on solar and wind energy sources is designed, simulated and evaluated in terms of performance and economic interest. When there is a drop of power, fuel cells are used to manage the deficiency. The investigated system is situated in Lebanon and the sizing takes into account the surrounding conditions such as meteorological data and particularities of the Lebanese situation. The main objective is to optimize the design such as the PV, wind and FC system would fully supply a typical 5 kW residential unit in Lebanon without any need for backup. A cost study is carried out in order to evaluate the effectiveness of such solution and whether it is applicable or of interest.\",\"PeriodicalId\":181607,\"journal\":{\"name\":\"2021 IEEE 3rd International Multidisciplinary Conference on Engineering Technology (IMCET)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 3rd International Multidisciplinary Conference on Engineering Technology (IMCET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/imcet53404.2021.9665498\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 3rd International Multidisciplinary Conference on Engineering Technology (IMCET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/imcet53404.2021.9665498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of the Effectiveness of Standalone Hybrid Systems for Small Residential Units: Case Study Lebanon
In this paper, a hybrid system based on solar and wind energy sources is designed, simulated and evaluated in terms of performance and economic interest. When there is a drop of power, fuel cells are used to manage the deficiency. The investigated system is situated in Lebanon and the sizing takes into account the surrounding conditions such as meteorological data and particularities of the Lebanese situation. The main objective is to optimize the design such as the PV, wind and FC system would fully supply a typical 5 kW residential unit in Lebanon without any need for backup. A cost study is carried out in order to evaluate the effectiveness of such solution and whether it is applicable or of interest.