用PMMA进行股骨近端骨增强的传导冷却方案:实验和有限元研究

Mahsan Bakhtiarinejad, Amirhossein Farvardin, A. Chamani, M. Armand
{"title":"用PMMA进行股骨近端骨增强的传导冷却方案:实验和有限元研究","authors":"Mahsan Bakhtiarinejad, Amirhossein Farvardin, A. Chamani, M. Armand","doi":"10.1115/imece2019-12142","DOIUrl":null,"url":null,"abstract":"\n The rate of one-year mortality after osteoporotic hip fracture in elderly is reported to be more than 20%. Hip augmentation using polymethylmethacrylate (PMMA) is an alternative preventive approach for patients at the highest risk of osteoporotic fracture. Excessive injection volumes of PMMA however may introduce the risk of thermal osteonecrosis. We have previously proposed a Finite element (FE) simulation to estimate the bone temperature elevations after cement injection in three key locations and demonstrated an agreement between the simulation results and the temperature measurements during the experiment. Previous study showed that the maximum temperature-rise measured at the hip surface is 10°C. The aim of this study is to introduce a cooling approach to reduce the PMMA’s curing temperature after cement injection during hip augmentation. For this purpose, we perform a conductive cooling experiment with a metallic K-wire attached to an ice-water bath. We also create a finite element simulation model for the proposed cooling system to estimate the peak temperature reduction and compare the simulation results with experimental data. Simulation results demonstrate the decrease of 80% of peak curing temperature during PMMA polymerization; similarly, sawbone experiments also show that on average the peak temperature has been reduced 64% when cooling system is integrated to the hip augmentation procedure.","PeriodicalId":332737,"journal":{"name":"Volume 3: Biomedical and Biotechnology Engineering","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Conductive Cooling Scheme for Bone Augmentation of the Proximal Femur With PMMA: An Experimental and Finite Element Study\",\"authors\":\"Mahsan Bakhtiarinejad, Amirhossein Farvardin, A. Chamani, M. Armand\",\"doi\":\"10.1115/imece2019-12142\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The rate of one-year mortality after osteoporotic hip fracture in elderly is reported to be more than 20%. Hip augmentation using polymethylmethacrylate (PMMA) is an alternative preventive approach for patients at the highest risk of osteoporotic fracture. Excessive injection volumes of PMMA however may introduce the risk of thermal osteonecrosis. We have previously proposed a Finite element (FE) simulation to estimate the bone temperature elevations after cement injection in three key locations and demonstrated an agreement between the simulation results and the temperature measurements during the experiment. Previous study showed that the maximum temperature-rise measured at the hip surface is 10°C. The aim of this study is to introduce a cooling approach to reduce the PMMA’s curing temperature after cement injection during hip augmentation. For this purpose, we perform a conductive cooling experiment with a metallic K-wire attached to an ice-water bath. We also create a finite element simulation model for the proposed cooling system to estimate the peak temperature reduction and compare the simulation results with experimental data. Simulation results demonstrate the decrease of 80% of peak curing temperature during PMMA polymerization; similarly, sawbone experiments also show that on average the peak temperature has been reduced 64% when cooling system is integrated to the hip augmentation procedure.\",\"PeriodicalId\":332737,\"journal\":{\"name\":\"Volume 3: Biomedical and Biotechnology Engineering\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3: Biomedical and Biotechnology Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece2019-12142\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Biomedical and Biotechnology Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2019-12142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

据报道,老年人骨质疏松性髋部骨折后一年的死亡率超过20%。使用聚甲基丙烯酸甲酯(PMMA)髋关节增强术是骨质疏松性骨折风险最高的患者的另一种预防方法。然而,过量的PMMA注射量可能会引入热骨坏死的风险。我们之前提出了一个有限元(FE)模拟来估计骨水泥注射后三个关键位置的骨温度升高,并证明了模拟结果与实验期间的温度测量之间的一致性。先前的研究表明,在臀部表面测量到的最大温升为10°C。本研究的目的是介绍一种冷却方法,以降低水泥注入后的PMMA的固化温度。为此,我们将金属k线连接到冰水浴中进行导电冷却实验。我们还对所提出的冷却系统建立了有限元模拟模型,以估计峰值温度降低,并将模拟结果与实验数据进行比较。模拟结果表明,PMMA聚合过程中峰值固化温度降低了80%;同样,锯齿实验也表明,当冷却系统集成到髋关节隆胸过程中时,峰值温度平均降低了64%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Conductive Cooling Scheme for Bone Augmentation of the Proximal Femur With PMMA: An Experimental and Finite Element Study
The rate of one-year mortality after osteoporotic hip fracture in elderly is reported to be more than 20%. Hip augmentation using polymethylmethacrylate (PMMA) is an alternative preventive approach for patients at the highest risk of osteoporotic fracture. Excessive injection volumes of PMMA however may introduce the risk of thermal osteonecrosis. We have previously proposed a Finite element (FE) simulation to estimate the bone temperature elevations after cement injection in three key locations and demonstrated an agreement between the simulation results and the temperature measurements during the experiment. Previous study showed that the maximum temperature-rise measured at the hip surface is 10°C. The aim of this study is to introduce a cooling approach to reduce the PMMA’s curing temperature after cement injection during hip augmentation. For this purpose, we perform a conductive cooling experiment with a metallic K-wire attached to an ice-water bath. We also create a finite element simulation model for the proposed cooling system to estimate the peak temperature reduction and compare the simulation results with experimental data. Simulation results demonstrate the decrease of 80% of peak curing temperature during PMMA polymerization; similarly, sawbone experiments also show that on average the peak temperature has been reduced 64% when cooling system is integrated to the hip augmentation procedure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信