用于内窥镜光学相干层析成像的可调谐扫描光纤mems探针

K. Aljasem, A. Seifert, H. Zappe
{"title":"用于内窥镜光学相干层析成像的可调谐扫描光纤mems探针","authors":"K. Aljasem, A. Seifert, H. Zappe","doi":"10.1109/MEMSYS.2009.4805555","DOIUrl":null,"url":null,"abstract":"A novel 3D probe for endoscopic optical coherence tomography (OCT) based on tunable and movable MEMS components is presented. A tunable micro-lens and a 2D scanning micro-mirror are integrated into a probe to enable two-dimensional movement with simultaneous dynamic focusing of a beam onto a target. The tunable system is based on a pneumatically actuated micro-lens for the axial movement of the focus position concomitantly with the depth scan of the OCT, whereas an electrostatically actuated micro-mirror is integrated to obtain the 2D lateral scan of the beam. High resolution imaging at high scan rates is expected for the entire scan depth using this concept. Probe design, assembly, and integration into an OCT system are discussed.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"121 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Tunable Scanning Fiber Optic MEMS-Probe for Endoscopic Optical Coherence Tomography\",\"authors\":\"K. Aljasem, A. Seifert, H. Zappe\",\"doi\":\"10.1109/MEMSYS.2009.4805555\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel 3D probe for endoscopic optical coherence tomography (OCT) based on tunable and movable MEMS components is presented. A tunable micro-lens and a 2D scanning micro-mirror are integrated into a probe to enable two-dimensional movement with simultaneous dynamic focusing of a beam onto a target. The tunable system is based on a pneumatically actuated micro-lens for the axial movement of the focus position concomitantly with the depth scan of the OCT, whereas an electrostatically actuated micro-mirror is integrated to obtain the 2D lateral scan of the beam. High resolution imaging at high scan rates is expected for the entire scan depth using this concept. Probe design, assembly, and integration into an OCT system are discussed.\",\"PeriodicalId\":187850,\"journal\":{\"name\":\"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems\",\"volume\":\"121 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.2009.4805555\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2009.4805555","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

提出了一种基于可调谐和可移动MEMS元件的内窥镜光学相干断层扫描(OCT)三维探头。一个可调微透镜和一个二维扫描微镜被集成到一个探针中,以实现二维运动,同时将光束动态聚焦到目标上。可调系统是基于一个气动驱动的微透镜,用于焦点位置的轴向移动,同时伴随OCT的深度扫描,而一个静电驱动的微镜集成,以获得光束的二维横向扫描。在高扫描速率下的高分辨率成像有望在整个扫描深度使用这一概念。探头的设计,组装和集成到OCT系统进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tunable Scanning Fiber Optic MEMS-Probe for Endoscopic Optical Coherence Tomography
A novel 3D probe for endoscopic optical coherence tomography (OCT) based on tunable and movable MEMS components is presented. A tunable micro-lens and a 2D scanning micro-mirror are integrated into a probe to enable two-dimensional movement with simultaneous dynamic focusing of a beam onto a target. The tunable system is based on a pneumatically actuated micro-lens for the axial movement of the focus position concomitantly with the depth scan of the OCT, whereas an electrostatically actuated micro-mirror is integrated to obtain the 2D lateral scan of the beam. High resolution imaging at high scan rates is expected for the entire scan depth using this concept. Probe design, assembly, and integration into an OCT system are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信