用空气摸胃

M. Kaneko, T. Kawahara, S. Matsunaga, T. Tsuji, Shinji Tanaka
{"title":"用空气摸胃","authors":"M. Kaneko, T. Kawahara, S. Matsunaga, T. Tsuji, Shinji Tanaka","doi":"10.1109/ROBOT.2003.1241670","DOIUrl":null,"url":null,"abstract":"This paper proposes a new endoscope system with an air injection based contact probe capable of measuring the local impedance of the inner surface of stomach. By utilizing air pressure, we can produce an equivalent contact force, which is really advantageous for avoiding any damage for stomach during an examination. A big issue is that there is no way to obtain the applied force to stomach exactly. The key for solving it is the specially designed solenoid valve with the response for more than 500 Hz. The solenoid valve with such a high response allows us to estimate each impedance parameter, even with a reference value. We show experimental system with a couple of interesting results.","PeriodicalId":315346,"journal":{"name":"2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)","volume":"131 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Touching stomach by air\",\"authors\":\"M. Kaneko, T. Kawahara, S. Matsunaga, T. Tsuji, Shinji Tanaka\",\"doi\":\"10.1109/ROBOT.2003.1241670\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a new endoscope system with an air injection based contact probe capable of measuring the local impedance of the inner surface of stomach. By utilizing air pressure, we can produce an equivalent contact force, which is really advantageous for avoiding any damage for stomach during an examination. A big issue is that there is no way to obtain the applied force to stomach exactly. The key for solving it is the specially designed solenoid valve with the response for more than 500 Hz. The solenoid valve with such a high response allows us to estimate each impedance parameter, even with a reference value. We show experimental system with a couple of interesting results.\",\"PeriodicalId\":315346,\"journal\":{\"name\":\"2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)\",\"volume\":\"131 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ROBOT.2003.1241670\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBOT.2003.1241670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

本文提出了一种新型的内窥镜系统,该系统采用基于空气喷射的接触式探头,能够测量胃内表面的局部阻抗。通过利用空气压力,我们可以产生等效的接触力,这对于避免在检查过程中对胃造成任何伤害是非常有利的。一个大问题是,没有办法准确地获得施加在胃上的力。解决这一问题的关键是专门设计的响应大于500hz的电磁阀。具有如此高响应的电磁阀使我们能够估计每个阻抗参数,甚至具有参考值。我们展示了一个实验系统,并得到了一些有趣的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Touching stomach by air
This paper proposes a new endoscope system with an air injection based contact probe capable of measuring the local impedance of the inner surface of stomach. By utilizing air pressure, we can produce an equivalent contact force, which is really advantageous for avoiding any damage for stomach during an examination. A big issue is that there is no way to obtain the applied force to stomach exactly. The key for solving it is the specially designed solenoid valve with the response for more than 500 Hz. The solenoid valve with such a high response allows us to estimate each impedance parameter, even with a reference value. We show experimental system with a couple of interesting results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信