基于花授粉算法的发电机实功率重调度拥塞管理

S. Deb, A. Goswami
{"title":"基于花授粉算法的发电机实功率重调度拥塞管理","authors":"S. Deb, A. Goswami","doi":"10.1109/CIEC.2016.7513805","DOIUrl":null,"url":null,"abstract":"Deregulation of electric power system has brought complexity in the system, competition among the electricity sellers and buyers which further creates overloading in transmission lines. Congestion occurs when undesirable transaction occurs through transmission lines during the transportation of electricity from generation to load centre. It is the duty of Independent System Operator (ISO) to ensure secure, reliable electricity transaction while facing the transmission congestion threat. This article presents a well known congestion management methodology i.e. rescheduling of generator output power in deregulated electricity market. In this work, firstly generator sensitivity factor (GSF) is calculated and based on these GSF values few generators are selected to reschedule their output for congestion management. A new meta-heuristic algorithm i.e. Flower Pollination Algorithm (FPA) has been adopted to reduce the generator rescheduling cost. The proposed work is verified on IEEE 39 bus New England system.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Congestion management by generator real power rescheduling using flower pollination algorithm\",\"authors\":\"S. Deb, A. Goswami\",\"doi\":\"10.1109/CIEC.2016.7513805\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Deregulation of electric power system has brought complexity in the system, competition among the electricity sellers and buyers which further creates overloading in transmission lines. Congestion occurs when undesirable transaction occurs through transmission lines during the transportation of electricity from generation to load centre. It is the duty of Independent System Operator (ISO) to ensure secure, reliable electricity transaction while facing the transmission congestion threat. This article presents a well known congestion management methodology i.e. rescheduling of generator output power in deregulated electricity market. In this work, firstly generator sensitivity factor (GSF) is calculated and based on these GSF values few generators are selected to reschedule their output for congestion management. A new meta-heuristic algorithm i.e. Flower Pollination Algorithm (FPA) has been adopted to reduce the generator rescheduling cost. The proposed work is verified on IEEE 39 bus New England system.\",\"PeriodicalId\":443343,\"journal\":{\"name\":\"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIEC.2016.7513805\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEC.2016.7513805","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

电力系统的放松管制带来了系统的复杂性,电力买卖双方之间的竞争进一步造成了输电线路的过载。当电力从发电厂输送到负荷中心的过程中,输电线路发生不希望发生的交易时,就会出现拥塞。在面对输电拥塞威胁的同时,确保安全、可靠的电力交易是独立系统运营商(ISO)的责任。本文提出了一种众所周知的拥塞管理方法,即在解除管制的电力市场中重新调度发电机输出功率。首先计算发电机灵敏度因子(GSF),并根据GSF值选择少量发电机重新调度其输出以进行拥塞管理。采用了一种新的元启发式算法——花授粉算法(Flower Pollination algorithm, FPA)来降低发电机的重调度成本。在ieee39总线新英格兰系统上对所提出的工作进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Congestion management by generator real power rescheduling using flower pollination algorithm
Deregulation of electric power system has brought complexity in the system, competition among the electricity sellers and buyers which further creates overloading in transmission lines. Congestion occurs when undesirable transaction occurs through transmission lines during the transportation of electricity from generation to load centre. It is the duty of Independent System Operator (ISO) to ensure secure, reliable electricity transaction while facing the transmission congestion threat. This article presents a well known congestion management methodology i.e. rescheduling of generator output power in deregulated electricity market. In this work, firstly generator sensitivity factor (GSF) is calculated and based on these GSF values few generators are selected to reschedule their output for congestion management. A new meta-heuristic algorithm i.e. Flower Pollination Algorithm (FPA) has been adopted to reduce the generator rescheduling cost. The proposed work is verified on IEEE 39 bus New England system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信