{"title":"“RADON-5E”便携式脉冲激光模拟器:描述、鉴定技术和结果、剂量测定程序","authors":"A. Nikiforov, O.B. Mavritsky, A. N. Egorov, V.S. Figurov, V. A. Telets, P.K. Skorobogatov, S.A. Polevich","doi":"10.1109/REDW.1996.574188","DOIUrl":null,"url":null,"abstract":"The original \"RADON-5E\" portable laser simulator for IC transient radiation effects investigation is developed and described. The parameters measurement procedure and qualification technique are worked out. The qualification tests results are presented. The dosimetry procedure is developed and \"calibration curves\" for several IC are measured in flash X-ray machine tests. Laser simulation errors were estimated in \"RADON-5E\" vs. flash X-ray machine comparative tests.","PeriodicalId":196196,"journal":{"name":"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"\\\"RADON-5E\\\" portable pulsed laser simulator: description, qualification technique and results, dosimetry procedure\",\"authors\":\"A. Nikiforov, O.B. Mavritsky, A. N. Egorov, V.S. Figurov, V. A. Telets, P.K. Skorobogatov, S.A. Polevich\",\"doi\":\"10.1109/REDW.1996.574188\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The original \\\"RADON-5E\\\" portable laser simulator for IC transient radiation effects investigation is developed and described. The parameters measurement procedure and qualification technique are worked out. The qualification tests results are presented. The dosimetry procedure is developed and \\\"calibration curves\\\" for several IC are measured in flash X-ray machine tests. Laser simulation errors were estimated in \\\"RADON-5E\\\" vs. flash X-ray machine comparative tests.\",\"PeriodicalId\":196196,\"journal\":{\"name\":\"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference\",\"volume\":\"98 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REDW.1996.574188\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REDW.1996.574188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The original "RADON-5E" portable laser simulator for IC transient radiation effects investigation is developed and described. The parameters measurement procedure and qualification technique are worked out. The qualification tests results are presented. The dosimetry procedure is developed and "calibration curves" for several IC are measured in flash X-ray machine tests. Laser simulation errors were estimated in "RADON-5E" vs. flash X-ray machine comparative tests.