“RADON-5E”便携式脉冲激光模拟器:描述、鉴定技术和结果、剂量测定程序

A. Nikiforov, O.B. Mavritsky, A. N. Egorov, V.S. Figurov, V. A. Telets, P.K. Skorobogatov, S.A. Polevich
{"title":"“RADON-5E”便携式脉冲激光模拟器:描述、鉴定技术和结果、剂量测定程序","authors":"A. Nikiforov, O.B. Mavritsky, A. N. Egorov, V.S. Figurov, V. A. Telets, P.K. Skorobogatov, S.A. Polevich","doi":"10.1109/REDW.1996.574188","DOIUrl":null,"url":null,"abstract":"The original \"RADON-5E\" portable laser simulator for IC transient radiation effects investigation is developed and described. The parameters measurement procedure and qualification technique are worked out. The qualification tests results are presented. The dosimetry procedure is developed and \"calibration curves\" for several IC are measured in flash X-ray machine tests. Laser simulation errors were estimated in \"RADON-5E\" vs. flash X-ray machine comparative tests.","PeriodicalId":196196,"journal":{"name":"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"\\\"RADON-5E\\\" portable pulsed laser simulator: description, qualification technique and results, dosimetry procedure\",\"authors\":\"A. Nikiforov, O.B. Mavritsky, A. N. Egorov, V.S. Figurov, V. A. Telets, P.K. Skorobogatov, S.A. Polevich\",\"doi\":\"10.1109/REDW.1996.574188\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The original \\\"RADON-5E\\\" portable laser simulator for IC transient radiation effects investigation is developed and described. The parameters measurement procedure and qualification technique are worked out. The qualification tests results are presented. The dosimetry procedure is developed and \\\"calibration curves\\\" for several IC are measured in flash X-ray machine tests. Laser simulation errors were estimated in \\\"RADON-5E\\\" vs. flash X-ray machine comparative tests.\",\"PeriodicalId\":196196,\"journal\":{\"name\":\"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference\",\"volume\":\"98 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REDW.1996.574188\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1996 IEEE Radiation Effects Data Workshop. Workshop Record. Held in conjunction with The IEEE Nuclear and Space Radiation Effects Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REDW.1996.574188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

研制并描述了用于集成电路瞬态辐射效应研究的原始便携式“RADON-5E”激光模拟器。制定了参数测量程序和鉴定技术。给出了鉴定试验结果。开发了剂量测定程序,并在闪光x射线机试验中测量了几种IC的“校准曲线”。在“RADON-5E”与闪光x射线机比较试验中估计了激光模拟误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
"RADON-5E" portable pulsed laser simulator: description, qualification technique and results, dosimetry procedure
The original "RADON-5E" portable laser simulator for IC transient radiation effects investigation is developed and described. The parameters measurement procedure and qualification technique are worked out. The qualification tests results are presented. The dosimetry procedure is developed and "calibration curves" for several IC are measured in flash X-ray machine tests. Laser simulation errors were estimated in "RADON-5E" vs. flash X-ray machine comparative tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信