{"title":"偏心运行永磁同步电机在线状态监测技术","authors":"J. Rosero, J. Ortega, A. Gacía, L. Romeral","doi":"10.1109/DEMPED.2007.4393077","DOIUrl":null,"url":null,"abstract":"This paper presents a study of the permanent magnet synchronous machine (PMSM) running under eccentricity fault. To carry out the study a two-dimensional (2-D) finite element analysis (FEA) is used. Relationships between stator current induced harmonics and dynamic air-gap eccentricity were investigated. Advanced signal analysis by means of continuous wavelet transforms was performed. Simulation were carried out and compared with experimental results .","PeriodicalId":185737,"journal":{"name":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","volume":"172 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"On-line condition monitoring technique for PMSM operated with eccentricity\",\"authors\":\"J. Rosero, J. Ortega, A. Gacía, L. Romeral\",\"doi\":\"10.1109/DEMPED.2007.4393077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a study of the permanent magnet synchronous machine (PMSM) running under eccentricity fault. To carry out the study a two-dimensional (2-D) finite element analysis (FEA) is used. Relationships between stator current induced harmonics and dynamic air-gap eccentricity were investigated. Advanced signal analysis by means of continuous wavelet transforms was performed. Simulation were carried out and compared with experimental results .\",\"PeriodicalId\":185737,\"journal\":{\"name\":\"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"volume\":\"172 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2007.4393077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2007.4393077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On-line condition monitoring technique for PMSM operated with eccentricity
This paper presents a study of the permanent magnet synchronous machine (PMSM) running under eccentricity fault. To carry out the study a two-dimensional (2-D) finite element analysis (FEA) is used. Relationships between stator current induced harmonics and dynamic air-gap eccentricity were investigated. Advanced signal analysis by means of continuous wavelet transforms was performed. Simulation were carried out and compared with experimental results .