{"title":"探地雷达穿壁人体呼吸监测新算法","authors":"Wenzhe Li, X. Jing, Zhao Li, Jianqi Wang","doi":"10.1109/ICGPR.2012.6254999","DOIUrl":null,"url":null,"abstract":"The ground penetrating radar (GPR) are widely used in recent years due to its potential applications and unique capabilities, especially in the earthquake search or rescue. In this paper, a novel adaptive line enhancer (ALE) algorithm for human respiration monitoring through obstacle with low-power GPR is presented. The results of through wall experiments show that it is feasible to use this algorithm to monitor the respiration of human target through the obstacle. The correlation of the human target's breathing rate between the simultaneously measured results obtained by our method and by the contact respiratory chest band using Biopac mpl50 measurement system is very good.","PeriodicalId":443640,"journal":{"name":"2012 14th International Conference on Ground Penetrating Radar (GPR)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A new algorithm for through wall human respiration monioring using GPR\",\"authors\":\"Wenzhe Li, X. Jing, Zhao Li, Jianqi Wang\",\"doi\":\"10.1109/ICGPR.2012.6254999\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ground penetrating radar (GPR) are widely used in recent years due to its potential applications and unique capabilities, especially in the earthquake search or rescue. In this paper, a novel adaptive line enhancer (ALE) algorithm for human respiration monitoring through obstacle with low-power GPR is presented. The results of through wall experiments show that it is feasible to use this algorithm to monitor the respiration of human target through the obstacle. The correlation of the human target's breathing rate between the simultaneously measured results obtained by our method and by the contact respiratory chest band using Biopac mpl50 measurement system is very good.\",\"PeriodicalId\":443640,\"journal\":{\"name\":\"2012 14th International Conference on Ground Penetrating Radar (GPR)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 14th International Conference on Ground Penetrating Radar (GPR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICGPR.2012.6254999\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 14th International Conference on Ground Penetrating Radar (GPR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICGPR.2012.6254999","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

近年来,探地雷达以其潜在的应用前景和独特的性能,特别是在地震搜救中得到了广泛的应用。本文提出了一种用于低功率探地雷达障碍物监测的自适应线增强算法。穿墙实验结果表明,将该算法应用于穿过障碍物监测人体目标的呼吸是可行的。用该方法测得的人体目标呼吸频率与使用Biopac mpl50测量系统的接触式呼吸带测得的人体目标呼吸频率具有很好的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new algorithm for through wall human respiration monioring using GPR
The ground penetrating radar (GPR) are widely used in recent years due to its potential applications and unique capabilities, especially in the earthquake search or rescue. In this paper, a novel adaptive line enhancer (ALE) algorithm for human respiration monitoring through obstacle with low-power GPR is presented. The results of through wall experiments show that it is feasible to use this algorithm to monitor the respiration of human target through the obstacle. The correlation of the human target's breathing rate between the simultaneously measured results obtained by our method and by the contact respiratory chest band using Biopac mpl50 measurement system is very good.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信