前庭-眼反射功能自动检测

Tainsong Chen, T. Tsai, Ming-Chi Shieh
{"title":"前庭-眼反射功能自动检测","authors":"Tainsong Chen, T. Tsai, Ming-Chi Shieh","doi":"10.1109/CBMS.1993.263018","DOIUrl":null,"url":null,"abstract":"The authors present an automatic vestibulo-ocular reflex (VOR) function test system which includes the following parts: a PC-controlled rotation chair provides the sinusoidal stimuli pattern (0.1 Hz approximately 2.0 Hz) for semicircular canal acceleration input; an electronic circuit amplifies the DC electro-oculography (EOG) signals for recording the eye movement; an efficient algorithm removes the fast phase of nystagmus to reconstruct the slow phase. From the observation of magnitude gain and phase shift between the semicircular canal sinusoidal acceleration input and the eye movement, we can test the vestibular function for clinical purposes. For normal people, the unity gain and 180 degree phase shift. This system will allow the clinician to diagnose patients with vertigo, dizziness and disequilibrium.<<ETX>>","PeriodicalId":250310,"journal":{"name":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Automatic examination for vestibulo-ocular reflex function test\",\"authors\":\"Tainsong Chen, T. Tsai, Ming-Chi Shieh\",\"doi\":\"10.1109/CBMS.1993.263018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors present an automatic vestibulo-ocular reflex (VOR) function test system which includes the following parts: a PC-controlled rotation chair provides the sinusoidal stimuli pattern (0.1 Hz approximately 2.0 Hz) for semicircular canal acceleration input; an electronic circuit amplifies the DC electro-oculography (EOG) signals for recording the eye movement; an efficient algorithm removes the fast phase of nystagmus to reconstruct the slow phase. From the observation of magnitude gain and phase shift between the semicircular canal sinusoidal acceleration input and the eye movement, we can test the vestibular function for clinical purposes. For normal people, the unity gain and 180 degree phase shift. This system will allow the clinician to diagnose patients with vertigo, dizziness and disequilibrium.<<ETX>>\",\"PeriodicalId\":250310,\"journal\":{\"name\":\"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMS.1993.263018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1993] Computer-Based Medical Systems-Proceedings of the Sixth Annual IEEE Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.1993.263018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

作者提出了一种自动前庭-眼反射(VOR)功能测试系统,该系统包括以下部分:由pc控制的旋转椅提供正弦波刺激模式(0.1 Hz约2.0 Hz),用于半规管加速输入;电子电路放大用于记录眼球运动的直流眼电(EOG)信号;一种有效的算法去除眼球震颤的快相,重建慢相。通过观察半圆管正弦加速度输入与眼动之间的幅度增益和相移,可以对前庭功能进行临床测试。对于普通人来说,单位增益和180度相移。该系统将允许临床医生诊断眩晕、头晕和不平衡的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic examination for vestibulo-ocular reflex function test
The authors present an automatic vestibulo-ocular reflex (VOR) function test system which includes the following parts: a PC-controlled rotation chair provides the sinusoidal stimuli pattern (0.1 Hz approximately 2.0 Hz) for semicircular canal acceleration input; an electronic circuit amplifies the DC electro-oculography (EOG) signals for recording the eye movement; an efficient algorithm removes the fast phase of nystagmus to reconstruct the slow phase. From the observation of magnitude gain and phase shift between the semicircular canal sinusoidal acceleration input and the eye movement, we can test the vestibular function for clinical purposes. For normal people, the unity gain and 180 degree phase shift. This system will allow the clinician to diagnose patients with vertigo, dizziness and disequilibrium.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信