{"title":"用于生理信息监测的可再生表面声波(SAW)免疫传感器","authors":"Koji Toma, Koki Oishi, T. Arakawa, K. Mitsubayashi, Naoyuki Yoshimura, H. Yatsuda","doi":"10.1109/ICSENST.2017.8304450","DOIUrl":null,"url":null,"abstract":"A reusable immunosensor that employed surface acoustic wave (SAW) was developed for monitoring of physiological information. The SAW immunosensor was fabricated by modifying a propagation area of the SAW device with a self-assembled monolayer of pH tolerant protein, ORLA85, which allowed repeating of surface regeneration by changing pH, and thereby rapid and repetitive (semi-continuous) measurement of analyte concentration. In experiment, initially a SAW device used for the sensor was characterized using a series of solution with various viscosity, and results showed a good correlation between phase change and solution viscosity from 0.88 to 1.7 mPa-s. In addition, performance of developed SAW immunosensor was evaluated using mouse IgG and anti-mouse IgG as model capturing molecule and analyte. It revealed that dynamic range of the immunosensor was 0.16–100 μg/mL with a measurement time of 20 minutes, and semi-continuous measurement was possible with a high reproducibility represented by a coefficient of variation of 3.4% for five repetitive measurement. These demonstrated that SAW immunosensor holds a huge potential for application to monitoring of time course of biomolecules which reflect physiological conditions.","PeriodicalId":289209,"journal":{"name":"2017 Eleventh International Conference on Sensing Technology (ICST)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Regeneratable surface acoustic wave (SAW) immunosensor for monitoring of physiological information\",\"authors\":\"Koji Toma, Koki Oishi, T. Arakawa, K. Mitsubayashi, Naoyuki Yoshimura, H. Yatsuda\",\"doi\":\"10.1109/ICSENST.2017.8304450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A reusable immunosensor that employed surface acoustic wave (SAW) was developed for monitoring of physiological information. The SAW immunosensor was fabricated by modifying a propagation area of the SAW device with a self-assembled monolayer of pH tolerant protein, ORLA85, which allowed repeating of surface regeneration by changing pH, and thereby rapid and repetitive (semi-continuous) measurement of analyte concentration. In experiment, initially a SAW device used for the sensor was characterized using a series of solution with various viscosity, and results showed a good correlation between phase change and solution viscosity from 0.88 to 1.7 mPa-s. In addition, performance of developed SAW immunosensor was evaluated using mouse IgG and anti-mouse IgG as model capturing molecule and analyte. It revealed that dynamic range of the immunosensor was 0.16–100 μg/mL with a measurement time of 20 minutes, and semi-continuous measurement was possible with a high reproducibility represented by a coefficient of variation of 3.4% for five repetitive measurement. These demonstrated that SAW immunosensor holds a huge potential for application to monitoring of time course of biomolecules which reflect physiological conditions.\",\"PeriodicalId\":289209,\"journal\":{\"name\":\"2017 Eleventh International Conference on Sensing Technology (ICST)\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Eleventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2017.8304450\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Eleventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2017.8304450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研制了一种可重复使用的表面声波免疫传感器,用于生理信息的监测。SAW免疫传感器是通过用一层自组装的耐pH蛋白ORLA85修饰SAW装置的繁殖区域来制造的,这种耐pH蛋白允许通过改变pH来重复表面再生,从而可以快速重复(半连续)测量分析物浓度。在实验中,首先使用一系列不同粘度的溶液对用于传感器的SAW器件进行了表征,结果表明,在0.88 ~ 1.7 mPa-s范围内,相变与溶液粘度之间存在良好的相关性。此外,以小鼠IgG和抗小鼠IgG作为模型捕获分子和分析物,对所研制的SAW免疫传感器的性能进行了评价。结果表明,该免疫传感器的动态范围为0.16 ~ 100 μg/mL,测量时间为20 min,可实现半连续测量,重复性高,5次重复测量的变异系数为3.4%。这表明SAW免疫传感器在监测反映生理状况的生物分子的时间过程方面具有巨大的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Regeneratable surface acoustic wave (SAW) immunosensor for monitoring of physiological information
A reusable immunosensor that employed surface acoustic wave (SAW) was developed for monitoring of physiological information. The SAW immunosensor was fabricated by modifying a propagation area of the SAW device with a self-assembled monolayer of pH tolerant protein, ORLA85, which allowed repeating of surface regeneration by changing pH, and thereby rapid and repetitive (semi-continuous) measurement of analyte concentration. In experiment, initially a SAW device used for the sensor was characterized using a series of solution with various viscosity, and results showed a good correlation between phase change and solution viscosity from 0.88 to 1.7 mPa-s. In addition, performance of developed SAW immunosensor was evaluated using mouse IgG and anti-mouse IgG as model capturing molecule and analyte. It revealed that dynamic range of the immunosensor was 0.16–100 μg/mL with a measurement time of 20 minutes, and semi-continuous measurement was possible with a high reproducibility represented by a coefficient of variation of 3.4% for five repetitive measurement. These demonstrated that SAW immunosensor holds a huge potential for application to monitoring of time course of biomolecules which reflect physiological conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信