用于2.4 GHz ISM频段医疗保健应用的IEEE 802.15.4射频发射机

Liang-Hung Wang, Tsung-Yen Chen, Huan Chen, Y. Chen, Q. Fang, Shuenn-Yuh Lee
{"title":"用于2.4 GHz ISM频段医疗保健应用的IEEE 802.15.4射频发射机","authors":"Liang-Hung Wang, Tsung-Yen Chen, Huan Chen, Y. Chen, Q. Fang, Shuenn-Yuh Lee","doi":"10.1109/ISBB.2011.6107644","DOIUrl":null,"url":null,"abstract":"This paper presents a low-power RF-transmitter for intelligent healthcare systems. With attention to power-efficient communication in the local sensor network, the required low-power integrated circuits (ICs) are developed for a healthcare system with miniaturization and system integration. A quadrature CMOS voltage-controlled oscillator and a direct-conversion transmitter with PA and up-conversion mixer have been implemented to fit the specification of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the transmitter have been applied in the TSMC 0.18-μm CMOS standard process. The measurement results reveal that the transmitter IC can fit in with the link budget of the UHF ZigBee system for healthcare applications.","PeriodicalId":345164,"journal":{"name":"International Symposium on Bioelectronics and Bioinformations 2011","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"An IEEE 802.15.4 RF transmitter for 2.4 GHz ISM band healthcare applications\",\"authors\":\"Liang-Hung Wang, Tsung-Yen Chen, Huan Chen, Y. Chen, Q. Fang, Shuenn-Yuh Lee\",\"doi\":\"10.1109/ISBB.2011.6107644\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a low-power RF-transmitter for intelligent healthcare systems. With attention to power-efficient communication in the local sensor network, the required low-power integrated circuits (ICs) are developed for a healthcare system with miniaturization and system integration. A quadrature CMOS voltage-controlled oscillator and a direct-conversion transmitter with PA and up-conversion mixer have been implemented to fit the specification of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the transmitter have been applied in the TSMC 0.18-μm CMOS standard process. The measurement results reveal that the transmitter IC can fit in with the link budget of the UHF ZigBee system for healthcare applications.\",\"PeriodicalId\":345164,\"journal\":{\"name\":\"International Symposium on Bioelectronics and Bioinformations 2011\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Bioelectronics and Bioinformations 2011\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBB.2011.6107644\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Bioelectronics and Bioinformations 2011","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBB.2011.6107644","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文介绍了一种用于智能医疗保健系统的低功率射频发射机。为了满足医疗保健系统小型化和系统集成化的要求,需要开发低功耗集成电路(ic),以提高本地传感器网络的通信效率。为了满足IEEE 802.15.4 2.4 GHz标准的要求,实现了一个正交CMOS压控振荡器和一个带PA和上转换混频器的直接转换发射机。该发射器的低功耗集成电路已应用于TSMC 0.18-μm CMOS标准工艺。测试结果表明,该发射机IC可以满足医疗保健应用UHF ZigBee系统的链路预算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An IEEE 802.15.4 RF transmitter for 2.4 GHz ISM band healthcare applications
This paper presents a low-power RF-transmitter for intelligent healthcare systems. With attention to power-efficient communication in the local sensor network, the required low-power integrated circuits (ICs) are developed for a healthcare system with miniaturization and system integration. A quadrature CMOS voltage-controlled oscillator and a direct-conversion transmitter with PA and up-conversion mixer have been implemented to fit the specification of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the transmitter have been applied in the TSMC 0.18-μm CMOS standard process. The measurement results reveal that the transmitter IC can fit in with the link budget of the UHF ZigBee system for healthcare applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信