基于微控制器的生理传感数据记录仪

E. Luharuka, R. Gao
{"title":"基于微控制器的生理传感数据记录仪","authors":"E. Luharuka, R. Gao","doi":"10.1109/IMTC.2002.1006836","DOIUrl":null,"url":null,"abstract":"The design and implementation of a microcontroller-based data logger for recording physiological data is presented. The device is designed to receive galvanic skin response (GSR) data from a commercial GSR instrument, store them on its on-board memory, and relay them later to a computer via the serial port. The focus of the design is on portability and low power consumption for battery-driven ambulatory applications. A special data compression algorithm is developed to optimize the on-board memory usage and reduce the data transfer time to a computer. A PIC microcontroller is used as the central control unit for the data flow coordination. The data logger prototype measures 18/spl times/9/spl times/3 cm, and can be readily miniaturized using SMT or hybrid techniques.","PeriodicalId":141111,"journal":{"name":"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A microcontroller-based data logger for physiological sensing\",\"authors\":\"E. Luharuka, R. Gao\",\"doi\":\"10.1109/IMTC.2002.1006836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The design and implementation of a microcontroller-based data logger for recording physiological data is presented. The device is designed to receive galvanic skin response (GSR) data from a commercial GSR instrument, store them on its on-board memory, and relay them later to a computer via the serial port. The focus of the design is on portability and low power consumption for battery-driven ambulatory applications. A special data compression algorithm is developed to optimize the on-board memory usage and reduce the data transfer time to a computer. A PIC microcontroller is used as the central control unit for the data flow coordination. The data logger prototype measures 18/spl times/9/spl times/3 cm, and can be readily miniaturized using SMT or hybrid techniques.\",\"PeriodicalId\":141111,\"journal\":{\"name\":\"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.2002.1006836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2002.1006836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

介绍了一种基于单片机的生理数据记录仪的设计与实现。该设备被设计用于接收来自商用GSR仪器的皮肤电反应(GSR)数据,将它们存储在其板载存储器中,然后通过串行端口将它们中继到计算机。设计的重点是便携性和低功耗的电池驱动的移动应用。提出了一种特殊的数据压缩算法,以优化板载内存的使用,减少数据传输到计算机的时间。采用PIC微控制器作为数据流协调的中央控制单元。数据记录仪原型测量18/spl次/9/spl次/3厘米,并且可以使用SMT或混合技术轻松小型化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A microcontroller-based data logger for physiological sensing
The design and implementation of a microcontroller-based data logger for recording physiological data is presented. The device is designed to receive galvanic skin response (GSR) data from a commercial GSR instrument, store them on its on-board memory, and relay them later to a computer via the serial port. The focus of the design is on portability and low power consumption for battery-driven ambulatory applications. A special data compression algorithm is developed to optimize the on-board memory usage and reduce the data transfer time to a computer. A PIC microcontroller is used as the central control unit for the data flow coordination. The data logger prototype measures 18/spl times/9/spl times/3 cm, and can be readily miniaturized using SMT or hybrid techniques.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信