S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Pătru, R. Dinu
{"title":"关于led光源产生电磁干扰的思考","authors":"S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Pătru, R. Dinu","doi":"10.1109/PQEMC-LF58184.2023.10211262","DOIUrl":null,"url":null,"abstract":"In this paper, a series of theoretical and practical aspects are presented in the first instance that refer to the performances of a semi-anechoic chamber that exists within the profile laboratory at the National Institute for Research, Development and Testing in Electrical Engineering – ICMET Craiova. Measurements of electromagnetic disturbances were carried out at this location, which two LED lighting devices, namely a Flexi LED & Flash light tube and a LED projector, transmitted into the power supply network. Then the authors made a comparative analysis of the practical results obtained from these measurements of electromagnetic disturbances transmitted by conduction in one of the frequency domains (from 9 kHz to 30 MHz) provided by the reference standards.","PeriodicalId":341783,"journal":{"name":"2023 Power Quality and Electromagnetic Compatibility at Low Frequency (PQEMC-LF)","volume":"22 39","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Considerations on Electromagnetic Disturbances Produced by LEDs Light Sources\",\"authors\":\"S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Pătru, R. Dinu\",\"doi\":\"10.1109/PQEMC-LF58184.2023.10211262\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a series of theoretical and practical aspects are presented in the first instance that refer to the performances of a semi-anechoic chamber that exists within the profile laboratory at the National Institute for Research, Development and Testing in Electrical Engineering – ICMET Craiova. Measurements of electromagnetic disturbances were carried out at this location, which two LED lighting devices, namely a Flexi LED & Flash light tube and a LED projector, transmitted into the power supply network. Then the authors made a comparative analysis of the practical results obtained from these measurements of electromagnetic disturbances transmitted by conduction in one of the frequency domains (from 9 kHz to 30 MHz) provided by the reference standards.\",\"PeriodicalId\":341783,\"journal\":{\"name\":\"2023 Power Quality and Electromagnetic Compatibility at Low Frequency (PQEMC-LF)\",\"volume\":\"22 39\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 Power Quality and Electromagnetic Compatibility at Low Frequency (PQEMC-LF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PQEMC-LF58184.2023.10211262\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 Power Quality and Electromagnetic Compatibility at Low Frequency (PQEMC-LF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQEMC-LF58184.2023.10211262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在本文中,首先介绍了一系列理论和实践方面的问题,这些问题涉及到存在于国家电气工程研究、开发和测试研究所(ICMET Craiova)剖面实验室中的半消声室的性能。在这个位置进行了电磁干扰测量,两个LED照明设备,即Flexi LED & Flash灯管和LED投影仪,将其传输到供电网络中。然后,作者对参考标准所提供的9 kHz至30 MHz频率范围内的传导电磁干扰的实际测量结果进行了对比分析。
Considerations on Electromagnetic Disturbances Produced by LEDs Light Sources
In this paper, a series of theoretical and practical aspects are presented in the first instance that refer to the performances of a semi-anechoic chamber that exists within the profile laboratory at the National Institute for Research, Development and Testing in Electrical Engineering – ICMET Craiova. Measurements of electromagnetic disturbances were carried out at this location, which two LED lighting devices, namely a Flexi LED & Flash light tube and a LED projector, transmitted into the power supply network. Then the authors made a comparative analysis of the practical results obtained from these measurements of electromagnetic disturbances transmitted by conduction in one of the frequency domains (from 9 kHz to 30 MHz) provided by the reference standards.