微创双极技术是长融合治疗成人神经肌肉性脊柱侧凸的更好替代方案吗?

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
ACS Applied Bio Materials Pub Date : 2024-09-01 Epub Date: 2023-02-21 DOI:10.1177/21925682231159347
Stéphane Wolff, Pierre-Emmanuel Moreau, Lotfi Miladi, Guillaume Riouallon
{"title":"微创双极技术是长融合治疗成人神经肌肉性脊柱侧凸的更好替代方案吗?","authors":"Stéphane Wolff, Pierre-Emmanuel Moreau, Lotfi Miladi, Guillaume Riouallon","doi":"10.1177/21925682231159347","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Prospective cohort study.</p><p><strong>Objectives: </strong>To report the results for an alternative technique based on minimally invasive fusion-less surgery. This approach is original in that it corrects deformities by proximal and distal fixation, with reliable pelvic fixation through the use of iliosacral screws on osteoporotic bones.</p><p><strong>Methods: </strong>Adult cerebral palsy patients requiring spinal correction surgery were included prospectively between 2015 and 2019. The technique involved the use of a double-rod construct anchored proximally by four clawed hooks and distally by iliosacral screws, in a minimally invasive approach. Cobb angle and pelvic obliquity were measured before and after initial surgery and at final follow-up. Complications and functional results were reviewed. This group (P) was compared with a second group (R) of patients who underwent surgery between 2005 and 2015, for whom data were collected retrospectively.</p><p><strong>Results: </strong>Thirty-one patients were included in group P, and 15 in group R. The two groups were comparable for demographic data and deformity. At most recent follow-up (3 years for group P [2-6] and 5 years for group R [2-16]), neither correction nor surgical complications differed between the two groups. However, group P had 50% less blood loss and a lower medical complication rate than group R.</p><p><strong>Conclusions: </strong>Our results confirm the effectiveness of this minimally invasive technique for neuromuscular scoliosis in adults. The results were similar to those obtained with the usual techniques, but with fewer medical complications. Confirmation of these results is now required for a longer follow-up period.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11418735/pdf/","citationCount":"0","resultStr":"{\"title\":\"Is Minimally Invasive Bipolar Technique a Better Alternative to Long Fusion for Adult Neuromuscular Scoliosis?\",\"authors\":\"Stéphane Wolff, Pierre-Emmanuel Moreau, Lotfi Miladi, Guillaume Riouallon\",\"doi\":\"10.1177/21925682231159347\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Prospective cohort study.</p><p><strong>Objectives: </strong>To report the results for an alternative technique based on minimally invasive fusion-less surgery. This approach is original in that it corrects deformities by proximal and distal fixation, with reliable pelvic fixation through the use of iliosacral screws on osteoporotic bones.</p><p><strong>Methods: </strong>Adult cerebral palsy patients requiring spinal correction surgery were included prospectively between 2015 and 2019. The technique involved the use of a double-rod construct anchored proximally by four clawed hooks and distally by iliosacral screws, in a minimally invasive approach. Cobb angle and pelvic obliquity were measured before and after initial surgery and at final follow-up. Complications and functional results were reviewed. This group (P) was compared with a second group (R) of patients who underwent surgery between 2005 and 2015, for whom data were collected retrospectively.</p><p><strong>Results: </strong>Thirty-one patients were included in group P, and 15 in group R. The two groups were comparable for demographic data and deformity. At most recent follow-up (3 years for group P [2-6] and 5 years for group R [2-16]), neither correction nor surgical complications differed between the two groups. However, group P had 50% less blood loss and a lower medical complication rate than group R.</p><p><strong>Conclusions: </strong>Our results confirm the effectiveness of this minimally invasive technique for neuromuscular scoliosis in adults. The results were similar to those obtained with the usual techniques, but with fewer medical complications. Confirmation of these results is now required for a longer follow-up period.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11418735/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/21925682231159347\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/2/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/21925682231159347","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/2/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

研究设计前瞻性队列研究:报告一种基于微创无融合手术的替代技术的结果。这种方法的独创性在于,它通过近端和远端固定矫正畸形,并通过在骨质疏松的骨骼上使用髂骶螺钉进行可靠的骨盆固定:前瞻性纳入2015年至2019年期间需要进行脊柱矫正手术的成年脑瘫患者。该技术采用微创方法,使用双杆结构,近端由四个爪钩固定,远端由髂骶螺钉固定。在初次手术前后和最终随访时测量了Cobb角和骨盆倾斜度。复查了并发症和功能结果。该组患者(P)与2005年至2015年期间接受手术的第二组患者(R)进行了比较,后者的数据是回顾性收集的:P组有31名患者,R组有15名患者。两组患者的人口统计学数据和畸形情况相当。在最近的随访中(P组随访3年[2-6],R组随访5年[2-16]),两组患者的矫正效果和手术并发症均无差异。不过,P 组的失血量减少了 50%,医疗并发症发生率也低于 R 组:我们的研究结果证实了这种微创技术治疗成人神经肌肉性脊柱侧凸的有效性。结论:我们的研究结果证实了这种微创技术对成人神经肌肉性脊柱侧凸的有效性,其结果与常规技术相似,但医疗并发症较少。现在需要更长时间的随访来确认这些结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Is Minimally Invasive Bipolar Technique a Better Alternative to Long Fusion for Adult Neuromuscular Scoliosis?

Study design: Prospective cohort study.

Objectives: To report the results for an alternative technique based on minimally invasive fusion-less surgery. This approach is original in that it corrects deformities by proximal and distal fixation, with reliable pelvic fixation through the use of iliosacral screws on osteoporotic bones.

Methods: Adult cerebral palsy patients requiring spinal correction surgery were included prospectively between 2015 and 2019. The technique involved the use of a double-rod construct anchored proximally by four clawed hooks and distally by iliosacral screws, in a minimally invasive approach. Cobb angle and pelvic obliquity were measured before and after initial surgery and at final follow-up. Complications and functional results were reviewed. This group (P) was compared with a second group (R) of patients who underwent surgery between 2005 and 2015, for whom data were collected retrospectively.

Results: Thirty-one patients were included in group P, and 15 in group R. The two groups were comparable for demographic data and deformity. At most recent follow-up (3 years for group P [2-6] and 5 years for group R [2-16]), neither correction nor surgical complications differed between the two groups. However, group P had 50% less blood loss and a lower medical complication rate than group R.

Conclusions: Our results confirm the effectiveness of this minimally invasive technique for neuromuscular scoliosis in adults. The results were similar to those obtained with the usual techniques, but with fewer medical complications. Confirmation of these results is now required for a longer follow-up period.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信