由骨科住院医师执行的髋关节表面置换、金属对金属或金属对聚乙烯全髋关节置换术- mri与超声检查对假肿瘤检测的敏感性和特异性

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Rasmus T Mikkelsen, Martin Schou, Trine Torfing, Ole Graumann, Søren Overgaard, Claus Varnum
{"title":"由骨科住院医师执行的髋关节表面置换、金属对金属或金属对聚乙烯全髋关节置换术- mri与超声检查对假肿瘤检测的敏感性和特异性","authors":"Rasmus T Mikkelsen,&nbsp;Martin Schou,&nbsp;Trine Torfing,&nbsp;Ole Graumann,&nbsp;Søren Overgaard,&nbsp;Claus Varnum","doi":"10.1177/20584601231152396","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel.</p><p><strong>Purpose: </strong>We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients.</p><p><strong>Material and methods: </strong>We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard.</p><p><strong>Results: </strong>US had a sensitivity of 0.92 (95% CI 0.81-0.98) and specificity of 0.94 (95% CI 0.89-0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73-0.91) and a negative predictive value of 0.97 (95% CI 0.93-0.99). US performed similarly in obese and non-obese patients.</p><p><strong>Conclusions: </strong>US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs.</p>","PeriodicalId":72063,"journal":{"name":"Acta radiologica open","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/8e/05/10.1177_20584601231152396.PMC9909072.pdf","citationCount":"0","resultStr":"{\"title\":\"Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident.\",\"authors\":\"Rasmus T Mikkelsen,&nbsp;Martin Schou,&nbsp;Trine Torfing,&nbsp;Ole Graumann,&nbsp;Søren Overgaard,&nbsp;Claus Varnum\",\"doi\":\"10.1177/20584601231152396\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel.</p><p><strong>Purpose: </strong>We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients.</p><p><strong>Material and methods: </strong>We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard.</p><p><strong>Results: </strong>US had a sensitivity of 0.92 (95% CI 0.81-0.98) and specificity of 0.94 (95% CI 0.89-0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73-0.91) and a negative predictive value of 0.97 (95% CI 0.93-0.99). US performed similarly in obese and non-obese patients.</p><p><strong>Conclusions: </strong>US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs.</p>\",\"PeriodicalId\":72063,\"journal\":{\"name\":\"Acta radiologica open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/8e/05/10.1177_20584601231152396.PMC9909072.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/20584601231152396\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20584601231152396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:金属伪影还原序列磁共振成像(MRI)扫描是检测全髋关节置换术(THA)中金属碎片不良反应的常用方法。如果超声检查(美国)可以筛查是否需要核磁共振成像,可能会更快更便宜。然而,两者都需要训练有素的人员。目的:我们的目的是研究由骨科住院医师进行的US检测假肿瘤(PT)的敏感性和特异性,并与MRI进行比较。我们还研究了US在肥胖和非肥胖患者中检测PTs的敏感性和特异性。材料和方法:我们用MRI和超声检查了205例髋关节置换术患者,金属对金属或金属对聚乙烯THA。US由一名骨科住院医师执行,他接受了肌肉骨骼US标准化培训计划的培训。MRI结果作为金标准。结果:US检测PT的敏感性为0.92 (95% CI 0.81 ~ 0.98),特异性为0.94 (95% CI 0.89 ~ 0.97),阳性预测值为0.84 (95% CI 0.73 ~ 0.91),阴性预测值为0.97 (95% CI 0.93 ~ 0.99)。美国在肥胖和非肥胖患者中的表现相似。结论:US在骨科住院医师检测PT时具有很高的敏感性和特异性。训练有素的骨科医生可以在搜索PTs时筛选是否需要进行核磁共振扫描。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident.

Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident.

Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident.

Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident.

Background: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel.

Purpose: We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients.

Material and methods: We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard.

Results: US had a sensitivity of 0.92 (95% CI 0.81-0.98) and specificity of 0.94 (95% CI 0.89-0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73-0.91) and a negative predictive value of 0.97 (95% CI 0.93-0.99). US performed similarly in obese and non-obese patients.

Conclusions: US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信