早衰心室复合体(PVC)负担对结构正常心脏左心室的影响:特发性PVC在超声心动图上的血流动力学改变。

IF 1.8 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Tien-En Chen, Chun-Cheng Wang, Hong-Chi Ho, Yi-Ching Lai, Hung-Bin Wu, Yen-Nien Lin, Pei-Ying Pai
{"title":"早衰心室复合体(PVC)负担对结构正常心脏左心室的影响:特发性PVC在超声心动图上的血流动力学改变。","authors":"Tien-En Chen,&nbsp;Chun-Cheng Wang,&nbsp;Hong-Chi Ho,&nbsp;Yi-Ching Lai,&nbsp;Hung-Bin Wu,&nbsp;Yen-Nien Lin,&nbsp;Pei-Ying Pai","doi":"10.6515/ACS.202309_39(5).20230119A","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Premature ventricular complex (PVC) without structural heart disease is mostly viewed as a benign arrhythmia. However, the high burden of PVC causes cardiomyopathy due to intraventricular dyssynchrony. The effects of ectopic contraction on left ventricular (LV) hemodynamics in the structurally normal heart are unclear.</p><p><strong>Objectives: </strong>To examine the effect of PVC burden on LV dimension, LV systolic function, and intraventricular blood flow, and to determine whether ectopic ventricular contraction affects LV hemodynamics.</p><p><strong>Methods: </strong>Patients aged ≥ 18 years with PVC ≥ 5% on Holter recording were enrolled and divided into groups G1 (5-10%), G2 (10-20%), and G3 (≥ 20%). We excluded patients with structural heart diseases, pacemakers, and LV systolic dysfunction [LV ejection fraction (LVEF) < 50%]. Clinical characteristics and routine transthoracic echocardiography parameters were compared.</p><p><strong>Results: </strong>The end-systolic LV internal dimension increased according to the PVC burden from G1 to G3 (p = 0.001). LVEF was inversely associated with PVC burden from G1 to G3 (p = 0.002). The same pattern was seen for LV outflow tract (LVOT) maximal velocity (p = 0.005) and maximal pressure gradient (PG) (p = 0.005), LVOT velocity time integral (VTI) (p = 0.03) and LV stroke volume index (LVSI) (p = 0.008).</p><p><strong>Conclusions: </strong>Systolic function and LV end-systolic dimension were inversely associated with PVC burden. Decreased LVOT flow velocity and PG were related to increased PVC burden. LVOT VTI and LVSI were smaller when the PVC burden exceeded 20%. These negative hemodynamic manifestations of idiopathic PVC were considerable even in structure normal hearts, hence the early elimination of PVC is strongly advised.</p>","PeriodicalId":6957,"journal":{"name":"Acta Cardiologica Sinica","volume":"39 5","pages":"687-694"},"PeriodicalIF":1.8000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499960/pdf/acs-39-687.pdf","citationCount":"0","resultStr":"{\"title\":\"Impact of Premature Ventricular Complex (PVC) Burden on the Left Ventricle in the Structurally Normal Heart: Hemodynamic Alterations of Idiopathic PVC on Echocardiography.\",\"authors\":\"Tien-En Chen,&nbsp;Chun-Cheng Wang,&nbsp;Hong-Chi Ho,&nbsp;Yi-Ching Lai,&nbsp;Hung-Bin Wu,&nbsp;Yen-Nien Lin,&nbsp;Pei-Ying Pai\",\"doi\":\"10.6515/ACS.202309_39(5).20230119A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Premature ventricular complex (PVC) without structural heart disease is mostly viewed as a benign arrhythmia. However, the high burden of PVC causes cardiomyopathy due to intraventricular dyssynchrony. The effects of ectopic contraction on left ventricular (LV) hemodynamics in the structurally normal heart are unclear.</p><p><strong>Objectives: </strong>To examine the effect of PVC burden on LV dimension, LV systolic function, and intraventricular blood flow, and to determine whether ectopic ventricular contraction affects LV hemodynamics.</p><p><strong>Methods: </strong>Patients aged ≥ 18 years with PVC ≥ 5% on Holter recording were enrolled and divided into groups G1 (5-10%), G2 (10-20%), and G3 (≥ 20%). We excluded patients with structural heart diseases, pacemakers, and LV systolic dysfunction [LV ejection fraction (LVEF) < 50%]. Clinical characteristics and routine transthoracic echocardiography parameters were compared.</p><p><strong>Results: </strong>The end-systolic LV internal dimension increased according to the PVC burden from G1 to G3 (p = 0.001). LVEF was inversely associated with PVC burden from G1 to G3 (p = 0.002). The same pattern was seen for LV outflow tract (LVOT) maximal velocity (p = 0.005) and maximal pressure gradient (PG) (p = 0.005), LVOT velocity time integral (VTI) (p = 0.03) and LV stroke volume index (LVSI) (p = 0.008).</p><p><strong>Conclusions: </strong>Systolic function and LV end-systolic dimension were inversely associated with PVC burden. Decreased LVOT flow velocity and PG were related to increased PVC burden. LVOT VTI and LVSI were smaller when the PVC burden exceeded 20%. These negative hemodynamic manifestations of idiopathic PVC were considerable even in structure normal hearts, hence the early elimination of PVC is strongly advised.</p>\",\"PeriodicalId\":6957,\"journal\":{\"name\":\"Acta Cardiologica Sinica\",\"volume\":\"39 5\",\"pages\":\"687-694\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499960/pdf/acs-39-687.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Cardiologica Sinica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.6515/ACS.202309_39(5).20230119A\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Cardiologica Sinica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.6515/ACS.202309_39(5).20230119A","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:无结构性心脏病的室性早衰(PVC)常被认为是一种良性心律失常。然而,由于心室内非同步化,PVC的高负荷引起心肌病。在结构正常的心脏中,异位收缩对左室血流动力学的影响尚不清楚。目的:探讨室性早搏负荷对左室尺寸、左室收缩功能及室内血流的影响,探讨室性早搏异位收缩是否影响左室血流动力学。方法:选取年龄≥18岁、Holter记录PVC≥5%的患者分为G1组(5-10%)、G2组(10-20%)、G3组(≥20%)。我们排除了结构性心脏病、起搏器和左室收缩功能障碍(左室射血分数(LVEF) < 50%)的患者。临床特点与常规经胸超声心动图参数比较。结果:收缩期末期左室内部尺寸随PVC负荷的增加而增加(p = 0.001)。从G1到G3, LVEF与PVC负荷呈负相关(p = 0.002)。左室流出道(LVOT)最大流速(p = 0.005)、最大压力梯度(PG) (p = 0.005)、LVOT流速时间积分(VTI) (p = 0.03)和左室搏程容积指数(LVSI) (p = 0.008)也出现了相同的模式。结论:收缩功能和左室收缩期终末尺寸与PVC负荷呈负相关。LVOT流速和PG降低与PVC负荷增加有关。当PVC负荷超过20%时,LVOT、VTI和LVSI较小。即使在结构正常的心脏中,特发性聚氯乙烯的这些阴性血流动力学表现也是相当可观的,因此强烈建议尽早消除聚氯乙烯。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of Premature Ventricular Complex (PVC) Burden on the Left Ventricle in the Structurally Normal Heart: Hemodynamic Alterations of Idiopathic PVC on Echocardiography.

Background: Premature ventricular complex (PVC) without structural heart disease is mostly viewed as a benign arrhythmia. However, the high burden of PVC causes cardiomyopathy due to intraventricular dyssynchrony. The effects of ectopic contraction on left ventricular (LV) hemodynamics in the structurally normal heart are unclear.

Objectives: To examine the effect of PVC burden on LV dimension, LV systolic function, and intraventricular blood flow, and to determine whether ectopic ventricular contraction affects LV hemodynamics.

Methods: Patients aged ≥ 18 years with PVC ≥ 5% on Holter recording were enrolled and divided into groups G1 (5-10%), G2 (10-20%), and G3 (≥ 20%). We excluded patients with structural heart diseases, pacemakers, and LV systolic dysfunction [LV ejection fraction (LVEF) < 50%]. Clinical characteristics and routine transthoracic echocardiography parameters were compared.

Results: The end-systolic LV internal dimension increased according to the PVC burden from G1 to G3 (p = 0.001). LVEF was inversely associated with PVC burden from G1 to G3 (p = 0.002). The same pattern was seen for LV outflow tract (LVOT) maximal velocity (p = 0.005) and maximal pressure gradient (PG) (p = 0.005), LVOT velocity time integral (VTI) (p = 0.03) and LV stroke volume index (LVSI) (p = 0.008).

Conclusions: Systolic function and LV end-systolic dimension were inversely associated with PVC burden. Decreased LVOT flow velocity and PG were related to increased PVC burden. LVOT VTI and LVSI were smaller when the PVC burden exceeded 20%. These negative hemodynamic manifestations of idiopathic PVC were considerable even in structure normal hearts, hence the early elimination of PVC is strongly advised.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Cardiologica Sinica
Acta Cardiologica Sinica 医学-心血管系统
CiteScore
2.90
自引率
15.80%
发文量
144
审稿时长
>12 weeks
期刊介绍: Acta Cardiologica Sinica welcomes all the papers in the fields related to cardiovascular medicine including basic research, vascular biology, clinical pharmacology, clinical trial, critical care medicine, coronary artery disease, interventional cardiology, arrythmia and electrophysiology, atherosclerosis, hypertension, cardiomyopathy and heart failure, valvular and structure cardiac disease, pediatric cardiology, cardiovascular surgery, and so on. We received papers from more than 20 countries and areas of the world. Currently, 40% of the papers were submitted to Acta Cardiologica Sinica from Taiwan, 20% from China, and 20% from the other countries and areas in the world. The acceptance rate for publication was around 50% in general.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信