John B Wojcik, Keyur Desai, Konstantinos Avraam, Arno Vandebroek, Lloye M Dillon, Giorgia Giacomazzi, Charlotte Rypens, Joseph L Benci
{"title":"用17B4抗体克隆在多个染色平台上测量LAG-3的表达。","authors":"John B Wojcik, Keyur Desai, Konstantinos Avraam, Arno Vandebroek, Lloye M Dillon, Giorgia Giacomazzi, Charlotte Rypens, Joseph L Benci","doi":"10.5858/arpa.2022-0082-OA","DOIUrl":null,"url":null,"abstract":"<p><strong>Context.—: </strong>An immunohistochemistry (IHC) assay developed to detect lymphocyte-activation gene 3 (LAG-3), a novel immune checkpoint inhibitor target, has demonstrated high analytic precision and interlaboratory reproducibility using a Leica staining platform, but it has not been investigated on other IHC staining platforms.</p><p><strong>Objective.—: </strong>To evaluate the performance of LAG-3 IHC assays using the 17B4 antibody clone across widely used IHC staining platforms: Agilent/Dako Autostainer Link 48 and VENTANA BenchMark ULTRA compared to Leica BOND-RX (BOND-RX).</p><p><strong>Design.—: </strong>Eighty formalin-fixed, paraffin-embedded melanoma tissue blocks were cut into consecutive sections and evaluated using staining platform-specific IHC assays with the 17B4 antibody clone. Duplicate testing was performed on the BOND-RX platform to assess intraplatform agreement. LAG-3 expression using a numeric score was evaluated by a pathologist and with a digital scoring algorithm. LAG-3 positivity was determined from manual scores using a 1% or greater cutoff.</p><p><strong>Results.—: </strong>LAG-3 IHC staining patterns and intensities were visually similar across all 3 staining platforms. Spearman and Pearson correlations were 0.75 or greater for interplatform and BOND-RX intraplatform concordance when LAG-3 expression was evaluated with a numeric score determined by a pathologist. Correlation increased with a numeric score determined with a digital scoring algorithm (Spearman and Pearson correlations ≥0.88 for all comparisons). Overall percentage agreement was 77.5% or greater for interplatform and BOND-RX intraplatform comparisons when LAG-3 positivity was determined using a 1% or greater cutoff.</p><p><strong>Conclusions.—: </strong>Data presented here demonstrate that LAG-3 expression can be robustly and reproducibly assessed across 3 major commercial IHC staining platforms using the 17B4 antibody clone.</p>","PeriodicalId":8305,"journal":{"name":"Archives of pathology & laboratory medicine","volume":" ","pages":"1307-1314"},"PeriodicalIF":3.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of LAG-3 Expression Across Multiple Staining Platforms With the 17B4 Antibody Clone.\",\"authors\":\"John B Wojcik, Keyur Desai, Konstantinos Avraam, Arno Vandebroek, Lloye M Dillon, Giorgia Giacomazzi, Charlotte Rypens, Joseph L Benci\",\"doi\":\"10.5858/arpa.2022-0082-OA\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Context.—: </strong>An immunohistochemistry (IHC) assay developed to detect lymphocyte-activation gene 3 (LAG-3), a novel immune checkpoint inhibitor target, has demonstrated high analytic precision and interlaboratory reproducibility using a Leica staining platform, but it has not been investigated on other IHC staining platforms.</p><p><strong>Objective.—: </strong>To evaluate the performance of LAG-3 IHC assays using the 17B4 antibody clone across widely used IHC staining platforms: Agilent/Dako Autostainer Link 48 and VENTANA BenchMark ULTRA compared to Leica BOND-RX (BOND-RX).</p><p><strong>Design.—: </strong>Eighty formalin-fixed, paraffin-embedded melanoma tissue blocks were cut into consecutive sections and evaluated using staining platform-specific IHC assays with the 17B4 antibody clone. Duplicate testing was performed on the BOND-RX platform to assess intraplatform agreement. LAG-3 expression using a numeric score was evaluated by a pathologist and with a digital scoring algorithm. LAG-3 positivity was determined from manual scores using a 1% or greater cutoff.</p><p><strong>Results.—: </strong>LAG-3 IHC staining patterns and intensities were visually similar across all 3 staining platforms. Spearman and Pearson correlations were 0.75 or greater for interplatform and BOND-RX intraplatform concordance when LAG-3 expression was evaluated with a numeric score determined by a pathologist. Correlation increased with a numeric score determined with a digital scoring algorithm (Spearman and Pearson correlations ≥0.88 for all comparisons). Overall percentage agreement was 77.5% or greater for interplatform and BOND-RX intraplatform comparisons when LAG-3 positivity was determined using a 1% or greater cutoff.</p><p><strong>Conclusions.—: </strong>Data presented here demonstrate that LAG-3 expression can be robustly and reproducibly assessed across 3 major commercial IHC staining platforms using the 17B4 antibody clone.</p>\",\"PeriodicalId\":8305,\"journal\":{\"name\":\"Archives of pathology & laboratory medicine\",\"volume\":\" \",\"pages\":\"1307-1314\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of pathology & laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5858/arpa.2022-0082-OA\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of pathology & laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5858/arpa.2022-0082-OA","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
上下文。--:为检测淋巴细胞活化基因3(LAG-3)(一种新的免疫检查点抑制剂靶点)而开发的免疫组织化学(IHC)测定法已使用Leica染色平台证明了高分析精度和实验室间的可重复性,但尚未在其他IHC染色平台上进行研究。目标。--:为了评估在广泛使用的IHC染色平台上使用17B4抗体克隆的LAG-3 IHC测定的性能:与Leica BOND-RX(BOND-RX)相比,Agilent/Dako Autostainer Link 48和VENTANA BenchMark ULTRA。设计:80福尔马林固定,将石蜡包埋的黑色素瘤组织块切割成连续切片,并使用17B4抗体克隆的染色平台特异性IHC测定法进行评估。在BOND-RX平台上进行重复测试,以评估平台内一致性。使用数字评分的LAG-3表达由病理学家和数字评分算法评估。LAG-3阳性由手动评分确定,使用1%或更大的截止值。结果。--:LAG-3 IHC染色模式和强度在所有3个染色平台上在视觉上相似。当用病理学家确定的数字评分评估LAG-3表达时,平台间和BOND-RX平台内一致性的Spearman和Pearson相关性为0.75或更大。相关性随着用数字评分算法确定的数字评分而增加(所有比较的Spearman和Pearson相关性≥0.88)。当使用1%或更大的截止值确定LAG-3阳性时,平台间和BOND-RX平台内比较的总体一致性百分比为77.5%或更大。结论。--:本文提供的数据表明,使用17B4抗体克隆,LAG-3的表达可以在3个主要的商业IHC染色平台上进行稳健和可重复的评估。
Measurement of LAG-3 Expression Across Multiple Staining Platforms With the 17B4 Antibody Clone.
Context.—: An immunohistochemistry (IHC) assay developed to detect lymphocyte-activation gene 3 (LAG-3), a novel immune checkpoint inhibitor target, has demonstrated high analytic precision and interlaboratory reproducibility using a Leica staining platform, but it has not been investigated on other IHC staining platforms.
Objective.—: To evaluate the performance of LAG-3 IHC assays using the 17B4 antibody clone across widely used IHC staining platforms: Agilent/Dako Autostainer Link 48 and VENTANA BenchMark ULTRA compared to Leica BOND-RX (BOND-RX).
Design.—: Eighty formalin-fixed, paraffin-embedded melanoma tissue blocks were cut into consecutive sections and evaluated using staining platform-specific IHC assays with the 17B4 antibody clone. Duplicate testing was performed on the BOND-RX platform to assess intraplatform agreement. LAG-3 expression using a numeric score was evaluated by a pathologist and with a digital scoring algorithm. LAG-3 positivity was determined from manual scores using a 1% or greater cutoff.
Results.—: LAG-3 IHC staining patterns and intensities were visually similar across all 3 staining platforms. Spearman and Pearson correlations were 0.75 or greater for interplatform and BOND-RX intraplatform concordance when LAG-3 expression was evaluated with a numeric score determined by a pathologist. Correlation increased with a numeric score determined with a digital scoring algorithm (Spearman and Pearson correlations ≥0.88 for all comparisons). Overall percentage agreement was 77.5% or greater for interplatform and BOND-RX intraplatform comparisons when LAG-3 positivity was determined using a 1% or greater cutoff.
Conclusions.—: Data presented here demonstrate that LAG-3 expression can be robustly and reproducibly assessed across 3 major commercial IHC staining platforms using the 17B4 antibody clone.
期刊介绍:
Welcome to the website of the Archives of Pathology & Laboratory Medicine (APLM). This monthly, peer-reviewed journal of the College of American Pathologists offers global reach and highest measured readership among pathology journals.
Published since 1926, ARCHIVES was voted in 2009 the only pathology journal among the top 100 most influential journals of the past 100 years by the BioMedical and Life Sciences Division of the Special Libraries Association. Online access to the full-text and PDF files of APLM articles is free.