{"title":"新生儿胆红素血症POCT管理-核黄疸监测优化指南","authors":"Michel Vaubourdolle,&nbsp;Agnès Mailloux","doi":"10.1684/abc.2022.1774","DOIUrl":null,"url":null,"abstract":"<p><p>In pediatrics, accurate measurement of total serum bilirubin (TSB) is of major importance for reliable diagnosis and appropriate management of neonatal jaundice. However, several studies evidenced poor comparability of results obtained with the different available methods either in central lab or in POCT, on serum, capillary blood or transcutaneous. This situation is partly due to the lack of Reference Materials, especially for high bilirubin concentrations but also on poor communication between central lab and neonatology unit. To progress on these issues, we have compiled some data from CNRHP to propose guidelines for choice, use and management of POCT devices and to help clinical laboratories to achieve a better answer to clinical needs with specific local constraints. The results from several CNRHP studies are presented: traceability to International System of Units, inter-laboratories comparability, POCT vs central labs comparisons with POCT CO-oximeter or photometer, integration of transcutaneous bilirubinometer. We propose, based on an analysis of devices advantages and issues, guidelines to help labs either to improve neonates monitoring in their local context; we distinguished the choices inside laboratory for a better harmonization of results compared to published thresholds and outside lab contexts, to organize a coordinated chain with POCT devices, with capillary and/or transcutaneous approaches.</p>","PeriodicalId":7892,"journal":{"name":"Annales de biologie clinique","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"POCT management of neonatal bilirubinemia – guidelines for an optimization of kernicterus monitoring\",\"authors\":\"Michel Vaubourdolle,&nbsp;Agnès Mailloux\",\"doi\":\"10.1684/abc.2022.1774\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In pediatrics, accurate measurement of total serum bilirubin (TSB) is of major importance for reliable diagnosis and appropriate management of neonatal jaundice. However, several studies evidenced poor comparability of results obtained with the different available methods either in central lab or in POCT, on serum, capillary blood or transcutaneous. This situation is partly due to the lack of Reference Materials, especially for high bilirubin concentrations but also on poor communication between central lab and neonatology unit. To progress on these issues, we have compiled some data from CNRHP to propose guidelines for choice, use and management of POCT devices and to help clinical laboratories to achieve a better answer to clinical needs with specific local constraints. The results from several CNRHP studies are presented: traceability to International System of Units, inter-laboratories comparability, POCT vs central labs comparisons with POCT CO-oximeter or photometer, integration of transcutaneous bilirubinometer. We propose, based on an analysis of devices advantages and issues, guidelines to help labs either to improve neonates monitoring in their local context; we distinguished the choices inside laboratory for a better harmonization of results compared to published thresholds and outside lab contexts, to organize a coordinated chain with POCT devices, with capillary and/or transcutaneous approaches.</p>\",\"PeriodicalId\":7892,\"journal\":{\"name\":\"Annales de biologie clinique\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annales de biologie clinique\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1684/abc.2022.1774\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de biologie clinique","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1684/abc.2022.1774","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在儿科,准确测定血清总胆红素(TSB)对新生儿黄疸的可靠诊断和适当处理具有重要意义。然而,几项研究表明,在中心实验室或POCT、血清、毛细血管或经皮检测中,不同可用方法获得的结果可比性差。这种情况部分是由于缺乏参考材料,特别是高胆红素浓度,但中心实验室和新生儿单位之间沟通不良。为了在这些问题上取得进展,我们收集了CNRHP的一些数据,以提出POCT设备的选择、使用和管理指南,并帮助临床实验室更好地满足当地特定限制条件下的临床需求。本文介绍了CNRHP的几个研究结果:国际单位制的可追溯性、实验室间的可比性、POCT与中心实验室与POCT co -血氧仪或光度计的比较、经皮胆红素计的整合。在分析设备优势和问题的基础上,我们提出了指导方针,以帮助实验室在当地环境下改善新生儿监测;我们区分了实验室内部的选择,以便与公布的阈值和实验室外部环境更好地协调结果,组织一个与POCT设备、毛细管和/或经皮入路协调的链。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
POCT management of neonatal bilirubinemia – guidelines for an optimization of kernicterus monitoring

In pediatrics, accurate measurement of total serum bilirubin (TSB) is of major importance for reliable diagnosis and appropriate management of neonatal jaundice. However, several studies evidenced poor comparability of results obtained with the different available methods either in central lab or in POCT, on serum, capillary blood or transcutaneous. This situation is partly due to the lack of Reference Materials, especially for high bilirubin concentrations but also on poor communication between central lab and neonatology unit. To progress on these issues, we have compiled some data from CNRHP to propose guidelines for choice, use and management of POCT devices and to help clinical laboratories to achieve a better answer to clinical needs with specific local constraints. The results from several CNRHP studies are presented: traceability to International System of Units, inter-laboratories comparability, POCT vs central labs comparisons with POCT CO-oximeter or photometer, integration of transcutaneous bilirubinometer. We propose, based on an analysis of devices advantages and issues, guidelines to help labs either to improve neonates monitoring in their local context; we distinguished the choices inside laboratory for a better harmonization of results compared to published thresholds and outside lab contexts, to organize a coordinated chain with POCT devices, with capillary and/or transcutaneous approaches.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annales de biologie clinique
Annales de biologie clinique 医学-医学:研究与实验
CiteScore
0.80
自引率
20.00%
发文量
53
审稿时长
6-12 weeks
期刊介绍: Multidisciplinary information with direct relevance to everyday practice Annales de Biologie Clinique, the official journal of the French Society of Clinical Biology (SFBC), supports biologists in areas including continuing education, laboratory accreditation and technique validation. With original articles, abstracts and accounts of everyday practice, the journal provides details of advances in knowledge, techniques and equipment, as well as a forum for discussion open to the entire community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信