评价动脉自旋标记数据在临床队列中的三维立体定向表面投影绘制

IF 2.3 4区 医学 Q3 CLINICAL NEUROLOGY
Jalal B. Andre, Murat Alp Oztek, Yoshimi Anzai, Gregory J. Wilson, Mahmud Mossa-Basha, Daniel S. Hippe, Michael N. Hoff, Donna J. Cross, Satoshi Minoshima
{"title":"评价动脉自旋标记数据在临床队列中的三维立体定向表面投影绘制","authors":"Jalal B. Andre,&nbsp;Murat Alp Oztek,&nbsp;Yoshimi Anzai,&nbsp;Gregory J. Wilson,&nbsp;Mahmud Mossa-Basha,&nbsp;Daniel S. Hippe,&nbsp;Michael N. Hoff,&nbsp;Donna J. Cross,&nbsp;Satoshi Minoshima","doi":"10.1111/jon.13153","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background and Purpose</h3>\n \n <p>To assess the feasibility of 3-dimensional stereotactic surface projection (3D-SSP) as applied to arterial spin labeling (ASL) in a clinical pilot study.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A retrospective sample of 10 consecutive patients who underwent ASL as part of a clinically indicated MR examination was collected during this pilot study. Five additional subjects with normal cerebral perfusion served as a control group. Following voxel-wise M0-correction, cerebral blood flow (CBF) quantification, and stereotactic anatomic standardization, voxel-wise CBF from an individual's ASL dataset was extracted to a set of predefined surface pixels (3D-SSP). A normal database was created from averaging the extracted CBF datasets of the control group. Patients’ datasets were compared individually with the normal database by calculating a <i>Z</i>-score on a pixel-by-pixel basis and were displayed in 3D-SSP views for visual inspection. Independent, two-expert reader assessment, using a 3-point scale, compared standard quantitative CBF images to the 3D-SSP maps.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Patterns and severities of regionally reduced CBF were identified, by both independent readers, in the 3D-SSP maps. Reader assessment demonstrated preference for 3D-SSP over traditionally displayed standard quantitative CBF images in three of four evaluated imaging metrics (<i>p</i> = .026, .031, and .013, respectively); 3D-SSP maps were never found to be inferior to the standard quantitative CBF images.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Three-dimensional SSP maps are feasible in a clinical population and enable quantitative data extraction and localization of perfusion abnormalities by means of stereotactic coordinates in a condensed display. The proposed method is a promising approach for interpreting cerebrovascular pathophysiology.</p>\n </section>\n </div>","PeriodicalId":16399,"journal":{"name":"Journal of Neuroimaging","volume":"33 6","pages":"933-940"},"PeriodicalIF":2.3000,"publicationDate":"2023-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of 3-dimensional stereotactic surface projection rendering of arterial spin labeling data in a clinical cohort\",\"authors\":\"Jalal B. Andre,&nbsp;Murat Alp Oztek,&nbsp;Yoshimi Anzai,&nbsp;Gregory J. Wilson,&nbsp;Mahmud Mossa-Basha,&nbsp;Daniel S. Hippe,&nbsp;Michael N. Hoff,&nbsp;Donna J. Cross,&nbsp;Satoshi Minoshima\",\"doi\":\"10.1111/jon.13153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background and Purpose</h3>\\n \\n <p>To assess the feasibility of 3-dimensional stereotactic surface projection (3D-SSP) as applied to arterial spin labeling (ASL) in a clinical pilot study.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A retrospective sample of 10 consecutive patients who underwent ASL as part of a clinically indicated MR examination was collected during this pilot study. Five additional subjects with normal cerebral perfusion served as a control group. Following voxel-wise M0-correction, cerebral blood flow (CBF) quantification, and stereotactic anatomic standardization, voxel-wise CBF from an individual's ASL dataset was extracted to a set of predefined surface pixels (3D-SSP). A normal database was created from averaging the extracted CBF datasets of the control group. Patients’ datasets were compared individually with the normal database by calculating a <i>Z</i>-score on a pixel-by-pixel basis and were displayed in 3D-SSP views for visual inspection. Independent, two-expert reader assessment, using a 3-point scale, compared standard quantitative CBF images to the 3D-SSP maps.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Patterns and severities of regionally reduced CBF were identified, by both independent readers, in the 3D-SSP maps. Reader assessment demonstrated preference for 3D-SSP over traditionally displayed standard quantitative CBF images in three of four evaluated imaging metrics (<i>p</i> = .026, .031, and .013, respectively); 3D-SSP maps were never found to be inferior to the standard quantitative CBF images.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Three-dimensional SSP maps are feasible in a clinical population and enable quantitative data extraction and localization of perfusion abnormalities by means of stereotactic coordinates in a condensed display. The proposed method is a promising approach for interpreting cerebrovascular pathophysiology.</p>\\n </section>\\n </div>\",\"PeriodicalId\":16399,\"journal\":{\"name\":\"Journal of Neuroimaging\",\"volume\":\"33 6\",\"pages\":\"933-940\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neuroimaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jon.13153\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neuroimaging","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jon.13153","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景与目的评价三维立体定向表面投影技术(3D-SSP)应用于动脉自旋标记(ASL)的可行性。方法在本初步研究中收集了10例连续接受ASL作为临床指示MR检查的患者的回顾性样本。另加5名脑灌注正常的受试者作为对照组。在体素方向的m0校正、脑血流量(CBF)量化和立体定向解剖标准化之后,将个体ASL数据集中的体素方向的CBF提取到一组预定义的表面像素(3D-SSP)。对对照组提取的CBF数据集取平均值,建立正常数据库。通过逐像素计算z分数,将患者数据集与正常数据库进行单独比较,并显示在3D-SSP视图中进行目视检查。独立的两位专家读者评估,使用3分制,将标准定量CBF图像与3D-SSP地图进行比较。结果两个独立的读者在3D-SSP图中识别了区域减少的CBF的模式和严重程度。在四项评估的成像指标中,读者评估显示3D-SSP优于传统显示的标准定量CBF图像(p分别= 0.026、0.031和0.013);从未发现3D-SSP图比标准定量CBF图像差。结论三维SSP图在临床人群中是可行的,可以通过浓缩显示器中的立体定向坐标进行定量数据提取和灌注异常定位。该方法是一种很有前途的解释脑血管病理生理的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of 3-dimensional stereotactic surface projection rendering of arterial spin labeling data in a clinical cohort

Background and Purpose

To assess the feasibility of 3-dimensional stereotactic surface projection (3D-SSP) as applied to arterial spin labeling (ASL) in a clinical pilot study.

Methods

A retrospective sample of 10 consecutive patients who underwent ASL as part of a clinically indicated MR examination was collected during this pilot study. Five additional subjects with normal cerebral perfusion served as a control group. Following voxel-wise M0-correction, cerebral blood flow (CBF) quantification, and stereotactic anatomic standardization, voxel-wise CBF from an individual's ASL dataset was extracted to a set of predefined surface pixels (3D-SSP). A normal database was created from averaging the extracted CBF datasets of the control group. Patients’ datasets were compared individually with the normal database by calculating a Z-score on a pixel-by-pixel basis and were displayed in 3D-SSP views for visual inspection. Independent, two-expert reader assessment, using a 3-point scale, compared standard quantitative CBF images to the 3D-SSP maps.

Results

Patterns and severities of regionally reduced CBF were identified, by both independent readers, in the 3D-SSP maps. Reader assessment demonstrated preference for 3D-SSP over traditionally displayed standard quantitative CBF images in three of four evaluated imaging metrics (p = .026, .031, and .013, respectively); 3D-SSP maps were never found to be inferior to the standard quantitative CBF images.

Conclusions

Three-dimensional SSP maps are feasible in a clinical population and enable quantitative data extraction and localization of perfusion abnormalities by means of stereotactic coordinates in a condensed display. The proposed method is a promising approach for interpreting cerebrovascular pathophysiology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Neuroimaging
Journal of Neuroimaging 医学-核医学
CiteScore
4.70
自引率
0.00%
发文量
117
审稿时长
6-12 weeks
期刊介绍: Start reading the Journal of Neuroimaging to learn the latest neurological imaging techniques. The peer-reviewed research is written in a practical clinical context, giving you the information you need on: MRI CT Carotid Ultrasound and TCD SPECT PET Endovascular Surgical Neuroradiology Functional MRI Xenon CT and other new and upcoming neuroscientific modalities.The Journal of Neuroimaging addresses the full spectrum of human nervous system disease, including stroke, neoplasia, degenerating and demyelinating disease, epilepsy, tumors, lesions, infectious disease, cerebral vascular arterial diseases, toxic-metabolic disease, psychoses, dementias, heredo-familial disease, and trauma.Offering original research, review articles, case reports, neuroimaging CPCs, and evaluations of instruments and technology relevant to the nervous system, the Journal of Neuroimaging focuses on useful clinical developments and applications, tested techniques and interpretations, patient care, diagnostics, and therapeutics. Start reading today!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信