Philip X Fuchs, Yi-Cheng Chou, Wei-Han Chen, Nicholas J Fiolo, Tzyy-Yuang Shiang
{"title":"本地定位系统对时间序列速度和加速度的精确度以及游戏运动中的性能指标。","authors":"Philip X Fuchs, Yi-Cheng Chou, Wei-Han Chen, Nicholas J Fiolo, Tzyy-Yuang Shiang","doi":"10.1080/14763141.2022.2110513","DOIUrl":null,"url":null,"abstract":"<p><p>The objective was to determine the reliability and validity of a local positioning system (LPS) promising high accuracy at reduced product costs. Fifty-five random static positions in a gym (54.8 × 26.0 m) were obtained 10 times via LPS (50 Hz) and measuring tape. An athlete's LPS-derived peak and time-series speed and acceleration during dynamic movements (<i>n</i> = 80) were compared with Vicon (100 Hz). Reliability and validity were assessed via Intraclass and Concordance Correlation Coefficients (ICC/CCC), root mean square errors, Bland-Altman plots, and analysis of variance. ICC<sub>3,1</sub> (≥0.999) and CCC (0.387-0.999) were calculated for static positions (errors <0.22 m). CCC for time-series speed and acceleration, and peak speed, acceleration, and deceleration were 0.884-0.902, 0.777-0.854, 0.923, 0.486, and 0.731, respectively. Errors were larger in time-series acceleration (14.37 ± 3.77%) than in speed (11.99 ± 5.78%) (<math><msubsup><mrow><mrow><mi>η</mi></mrow></mrow><mrow><mrow><mi>p</mi></mrow></mrow><mn>2</mn></msubsup></math> = 0.472, <i>p</i> < 0.001) and in peak acceleration (28.04 ± 14.34%) and deceleration (25.07 ± 14.90%) than in speed (7.34 ± 6.07%) (<math><msubsup><mrow><mrow><mi>η</mi></mrow></mrow><mrow><mrow><mi>p</mi></mrow></mrow><mn>2</mn></msubsup></math> = 0.091, <i>p</i> < 0.01). LPS achieved excellent reliability and moderate-to-excellent validity of time-series speed and acceleration. The system accurately measured peak speed but not peak acceleration and deceleration. The system is suitable for analyses based on instantaneous speed and acceleration in game sports (e.g., energy estimations).</p>","PeriodicalId":49482,"journal":{"name":"Sports Biomechanics","volume":" ","pages":"291-305"},"PeriodicalIF":2.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of a local positioning system for time-series speed and acceleration and performance indicators in game sports.\",\"authors\":\"Philip X Fuchs, Yi-Cheng Chou, Wei-Han Chen, Nicholas J Fiolo, Tzyy-Yuang Shiang\",\"doi\":\"10.1080/14763141.2022.2110513\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective was to determine the reliability and validity of a local positioning system (LPS) promising high accuracy at reduced product costs. Fifty-five random static positions in a gym (54.8 × 26.0 m) were obtained 10 times via LPS (50 Hz) and measuring tape. An athlete's LPS-derived peak and time-series speed and acceleration during dynamic movements (<i>n</i> = 80) were compared with Vicon (100 Hz). Reliability and validity were assessed via Intraclass and Concordance Correlation Coefficients (ICC/CCC), root mean square errors, Bland-Altman plots, and analysis of variance. ICC<sub>3,1</sub> (≥0.999) and CCC (0.387-0.999) were calculated for static positions (errors <0.22 m). CCC for time-series speed and acceleration, and peak speed, acceleration, and deceleration were 0.884-0.902, 0.777-0.854, 0.923, 0.486, and 0.731, respectively. Errors were larger in time-series acceleration (14.37 ± 3.77%) than in speed (11.99 ± 5.78%) (<math><msubsup><mrow><mrow><mi>η</mi></mrow></mrow><mrow><mrow><mi>p</mi></mrow></mrow><mn>2</mn></msubsup></math> = 0.472, <i>p</i> < 0.001) and in peak acceleration (28.04 ± 14.34%) and deceleration (25.07 ± 14.90%) than in speed (7.34 ± 6.07%) (<math><msubsup><mrow><mrow><mi>η</mi></mrow></mrow><mrow><mrow><mi>p</mi></mrow></mrow><mn>2</mn></msubsup></math> = 0.091, <i>p</i> < 0.01). LPS achieved excellent reliability and moderate-to-excellent validity of time-series speed and acceleration. The system accurately measured peak speed but not peak acceleration and deceleration. The system is suitable for analyses based on instantaneous speed and acceleration in game sports (e.g., energy estimations).</p>\",\"PeriodicalId\":49482,\"journal\":{\"name\":\"Sports Biomechanics\",\"volume\":\" \",\"pages\":\"291-305\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sports Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/14763141.2022.2110513\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sports Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/14763141.2022.2110513","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Accuracy of a local positioning system for time-series speed and acceleration and performance indicators in game sports.
The objective was to determine the reliability and validity of a local positioning system (LPS) promising high accuracy at reduced product costs. Fifty-five random static positions in a gym (54.8 × 26.0 m) were obtained 10 times via LPS (50 Hz) and measuring tape. An athlete's LPS-derived peak and time-series speed and acceleration during dynamic movements (n = 80) were compared with Vicon (100 Hz). Reliability and validity were assessed via Intraclass and Concordance Correlation Coefficients (ICC/CCC), root mean square errors, Bland-Altman plots, and analysis of variance. ICC3,1 (≥0.999) and CCC (0.387-0.999) were calculated for static positions (errors <0.22 m). CCC for time-series speed and acceleration, and peak speed, acceleration, and deceleration were 0.884-0.902, 0.777-0.854, 0.923, 0.486, and 0.731, respectively. Errors were larger in time-series acceleration (14.37 ± 3.77%) than in speed (11.99 ± 5.78%) ( = 0.472, p < 0.001) and in peak acceleration (28.04 ± 14.34%) and deceleration (25.07 ± 14.90%) than in speed (7.34 ± 6.07%) ( = 0.091, p < 0.01). LPS achieved excellent reliability and moderate-to-excellent validity of time-series speed and acceleration. The system accurately measured peak speed but not peak acceleration and deceleration. The system is suitable for analyses based on instantaneous speed and acceleration in game sports (e.g., energy estimations).
期刊介绍:
Sports Biomechanics is the Thomson Reuters listed scientific journal of the International Society of Biomechanics in Sports (ISBS). The journal sets out to generate knowledge to improve human performance and reduce the incidence of injury, and to communicate this knowledge to scientists, coaches, clinicians, teachers, and participants. The target performance realms include not only the conventional areas of sports and exercise, but also fundamental motor skills and other highly specialized human movements such as dance (both sport and artistic).
Sports Biomechanics is unique in its emphasis on a broad biomechanical spectrum of human performance including, but not limited to, technique, skill acquisition, training, strength and conditioning, exercise, coaching, teaching, equipment, modeling and simulation, measurement, and injury prevention and rehabilitation. As well as maintaining scientific rigour, there is a strong editorial emphasis on ''reader friendliness''. By emphasising the practical implications and applications of research, the journal seeks to benefit practitioners directly.
Sports Biomechanics publishes papers in four sections: Original Research, Reviews, Teaching, and Methods and Theoretical Perspectives.