{"title":"双太阳穴-乳突和双双耳20 Hz正弦波前庭电刺激引起的垂直感和体位摇摆的比较。","authors":"Samar Babaee, Moslem Shaabani, Mohsen Vahedi","doi":"10.3233/VES-210112","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Galvanic vestibular stimulation (GVS) is believed to be one of the most valuable tools for studying the vestibular system. In our opinion, its combined effect on posture and perception needs to be examined more.</p><p><strong>Objective: </strong>The present study was conducted to investigate the effect of a 20 Hz sinusoidal Galvanic Vestibular Stimulation (sGVS) on the body sway and subjective visual vertical (SVV) deviation through two sets of electrode montages (bipolar binaural and double temple-mastoidal stimulation) during a three-stage experiment (baseline, threshold, and supra-threshold levels).</p><p><strong>Methods: </strong>While the individuals (32 normal individuals, 10 males, the mean age of 25.37±3.00 years) were standing on a posturography device and SVV goggles were put on, the parameters of the body sway and SVV deviation were measured simultaneously. Following the baseline stage (measuring without stimulation), the parameters were investigated during the threshold and supra-threshold stages (1 mA above the threshold) for 20 seconds. This was done separately for each electrode montage. Then, the results were compared between the three experimental stages and the two electrode montages.</p><p><strong>Results: </strong>In both electrode montages, \"the maximum amplitude\" of the mediolateral (ML) and anteroposterior (AP) body sway decreased and increased in the threshold and supra-threshold stages, respectively, compared to the baseline stage. Comparison of the amount of \"amplitude change\" caused by each electrode montages showed that the double temple-mastoidal stimulation induced a significantly greater amplitude change in body sway during both threshold and supra-threshold stages (relative to the baseline stage).The absolute mean values of the SVV deviation were significantly different between the baseline and supra-threshold levels in both electrode montages. The SVV deviation in double temple-mastoidal stimulation was a bit greater than that in the bipolar binaural stimulation.</p><p><strong>Conclusion: </strong>Double temple-mastoidal stimulation has induced greater amount of change in the body sway and SVV deviation. This may be due to the more effective stimulation of the otoliths than semicircular canals.</p>","PeriodicalId":49960,"journal":{"name":"Journal of Vestibular Research-Equilibrium & Orientation","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of verticality perception and postural sway induced by double temple-mastoidal and bipolar binaural 20 Hz sinusoidal galvanic vestibular stimulation.\",\"authors\":\"Samar Babaee, Moslem Shaabani, Mohsen Vahedi\",\"doi\":\"10.3233/VES-210112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Galvanic vestibular stimulation (GVS) is believed to be one of the most valuable tools for studying the vestibular system. In our opinion, its combined effect on posture and perception needs to be examined more.</p><p><strong>Objective: </strong>The present study was conducted to investigate the effect of a 20 Hz sinusoidal Galvanic Vestibular Stimulation (sGVS) on the body sway and subjective visual vertical (SVV) deviation through two sets of electrode montages (bipolar binaural and double temple-mastoidal stimulation) during a three-stage experiment (baseline, threshold, and supra-threshold levels).</p><p><strong>Methods: </strong>While the individuals (32 normal individuals, 10 males, the mean age of 25.37±3.00 years) were standing on a posturography device and SVV goggles were put on, the parameters of the body sway and SVV deviation were measured simultaneously. Following the baseline stage (measuring without stimulation), the parameters were investigated during the threshold and supra-threshold stages (1 mA above the threshold) for 20 seconds. This was done separately for each electrode montage. Then, the results were compared between the three experimental stages and the two electrode montages.</p><p><strong>Results: </strong>In both electrode montages, \\\"the maximum amplitude\\\" of the mediolateral (ML) and anteroposterior (AP) body sway decreased and increased in the threshold and supra-threshold stages, respectively, compared to the baseline stage. Comparison of the amount of \\\"amplitude change\\\" caused by each electrode montages showed that the double temple-mastoidal stimulation induced a significantly greater amplitude change in body sway during both threshold and supra-threshold stages (relative to the baseline stage).The absolute mean values of the SVV deviation were significantly different between the baseline and supra-threshold levels in both electrode montages. The SVV deviation in double temple-mastoidal stimulation was a bit greater than that in the bipolar binaural stimulation.</p><p><strong>Conclusion: </strong>Double temple-mastoidal stimulation has induced greater amount of change in the body sway and SVV deviation. This may be due to the more effective stimulation of the otoliths than semicircular canals.</p>\",\"PeriodicalId\":49960,\"journal\":{\"name\":\"Journal of Vestibular Research-Equilibrium & Orientation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vestibular Research-Equilibrium & Orientation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/VES-210112\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vestibular Research-Equilibrium & Orientation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/VES-210112","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Comparison of verticality perception and postural sway induced by double temple-mastoidal and bipolar binaural 20 Hz sinusoidal galvanic vestibular stimulation.
Background: Galvanic vestibular stimulation (GVS) is believed to be one of the most valuable tools for studying the vestibular system. In our opinion, its combined effect on posture and perception needs to be examined more.
Objective: The present study was conducted to investigate the effect of a 20 Hz sinusoidal Galvanic Vestibular Stimulation (sGVS) on the body sway and subjective visual vertical (SVV) deviation through two sets of electrode montages (bipolar binaural and double temple-mastoidal stimulation) during a three-stage experiment (baseline, threshold, and supra-threshold levels).
Methods: While the individuals (32 normal individuals, 10 males, the mean age of 25.37±3.00 years) were standing on a posturography device and SVV goggles were put on, the parameters of the body sway and SVV deviation were measured simultaneously. Following the baseline stage (measuring without stimulation), the parameters were investigated during the threshold and supra-threshold stages (1 mA above the threshold) for 20 seconds. This was done separately for each electrode montage. Then, the results were compared between the three experimental stages and the two electrode montages.
Results: In both electrode montages, "the maximum amplitude" of the mediolateral (ML) and anteroposterior (AP) body sway decreased and increased in the threshold and supra-threshold stages, respectively, compared to the baseline stage. Comparison of the amount of "amplitude change" caused by each electrode montages showed that the double temple-mastoidal stimulation induced a significantly greater amplitude change in body sway during both threshold and supra-threshold stages (relative to the baseline stage).The absolute mean values of the SVV deviation were significantly different between the baseline and supra-threshold levels in both electrode montages. The SVV deviation in double temple-mastoidal stimulation was a bit greater than that in the bipolar binaural stimulation.
Conclusion: Double temple-mastoidal stimulation has induced greater amount of change in the body sway and SVV deviation. This may be due to the more effective stimulation of the otoliths than semicircular canals.
期刊介绍:
Journal of Vestibular Research is a peer-reviewed journal that publishes experimental and observational studies, review papers, and theoretical papers based on current knowledge of the vestibular system. Subjects of the studies can include experimental animals, normal humans, and humans with vestibular or other related disorders. Study topics can include the following:
Anatomy of the vestibular system, including vestibulo-ocular, vestibulo-spinal, and vestibulo-autonomic pathways
Balance disorders
Neurochemistry and neuropharmacology of balance, both at the systems and single neuron level
Neurophysiology of balance, including the vestibular, ocular motor, autonomic, and postural control systems
Psychophysics of spatial orientation
Space and motion sickness
Vestibular rehabilitation
Vestibular-related human performance in various environments