Anthony Nguyen, Brooke Draggoo, Brooklyn Tobias, Payton DuBose, Katharine Polasek
{"title":"电诱发的参照感觉诱导橡胶肢的具体化。","authors":"Anthony Nguyen, Brooke Draggoo, Brooklyn Tobias, Payton DuBose, Katharine Polasek","doi":"10.1177/20556683231183633","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Electrical stimulation is increasingly relevant in a variety of medical treatments. In this study, the quality of referred sensations evoked using surface electrical stimulation was evaluated using the rubber hand and foot illusions.</p><p><strong>Methods: </strong>The rubber hand and foot illusions were attempted under 4 conditions: (1) multi-location tapping; (2) one-location tapping; (3) electrical stimulation of sensation referred to the hand or foot; (4) asynchronous control. The strength of each illusion was quantified using a questionnaire and proprioceptive drift, where a stronger response suggested embodiment of the rubber limb.</p><p><strong>Results: </strong>45 able-bodied individuals and two individuals with amputations participated in this study. Overall, the illusion evoked by nerve stimulation was not as strong as illusions evoked by physically tapping but stronger than the control illusion.</p><p><strong>Conclusion: </strong>This study has found that the rubber hand and foot illusion can be performed without touching the distal limb of the participant. Electrical stimulation that produced referred sensation in the distal extremity was realistic enough to partially incorporate the rubber limb into a person's body image.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bb/23/10.1177_20556683231183633.PMC10328156.pdf","citationCount":"0","resultStr":"{\"title\":\"Electrically-evoked referred sensations induce embodiment of rubber limb.\",\"authors\":\"Anthony Nguyen, Brooke Draggoo, Brooklyn Tobias, Payton DuBose, Katharine Polasek\",\"doi\":\"10.1177/20556683231183633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Electrical stimulation is increasingly relevant in a variety of medical treatments. In this study, the quality of referred sensations evoked using surface electrical stimulation was evaluated using the rubber hand and foot illusions.</p><p><strong>Methods: </strong>The rubber hand and foot illusions were attempted under 4 conditions: (1) multi-location tapping; (2) one-location tapping; (3) electrical stimulation of sensation referred to the hand or foot; (4) asynchronous control. The strength of each illusion was quantified using a questionnaire and proprioceptive drift, where a stronger response suggested embodiment of the rubber limb.</p><p><strong>Results: </strong>45 able-bodied individuals and two individuals with amputations participated in this study. Overall, the illusion evoked by nerve stimulation was not as strong as illusions evoked by physically tapping but stronger than the control illusion.</p><p><strong>Conclusion: </strong>This study has found that the rubber hand and foot illusion can be performed without touching the distal limb of the participant. Electrical stimulation that produced referred sensation in the distal extremity was realistic enough to partially incorporate the rubber limb into a person's body image.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bb/23/10.1177_20556683231183633.PMC10328156.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/20556683231183633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20556683231183633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Electrically-evoked referred sensations induce embodiment of rubber limb.
Introduction: Electrical stimulation is increasingly relevant in a variety of medical treatments. In this study, the quality of referred sensations evoked using surface electrical stimulation was evaluated using the rubber hand and foot illusions.
Methods: The rubber hand and foot illusions were attempted under 4 conditions: (1) multi-location tapping; (2) one-location tapping; (3) electrical stimulation of sensation referred to the hand or foot; (4) asynchronous control. The strength of each illusion was quantified using a questionnaire and proprioceptive drift, where a stronger response suggested embodiment of the rubber limb.
Results: 45 able-bodied individuals and two individuals with amputations participated in this study. Overall, the illusion evoked by nerve stimulation was not as strong as illusions evoked by physically tapping but stronger than the control illusion.
Conclusion: This study has found that the rubber hand and foot illusion can be performed without touching the distal limb of the participant. Electrical stimulation that produced referred sensation in the distal extremity was realistic enough to partially incorporate the rubber limb into a person's body image.