Michał Bociański, Mateusz Puślecki, Anna Olasińska-Wiśniewska, Bartłomiej Perek, Sebastian Stefaniak, Piotr Buczkowski, Marek Jemielity
{"title":"无缝线生物与机械假体微创主动脉瓣置换术的比较研究。","authors":"Michał Bociański, Mateusz Puślecki, Anna Olasińska-Wiśniewska, Bartłomiej Perek, Sebastian Stefaniak, Piotr Buczkowski, Marek Jemielity","doi":"10.5114/kitp.2023.129542","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The ministernotomy approach with sutureless aortic bioprosthesis may provide an attractive and safe option for aortic valve disease patients.</p><p><strong>Aim: </strong>To assess the early and mid-term outcomes of minimally invasive aortic valve replacement (miniAVR) with sutureless vs. standard prostheses.</p><p><strong>Material and methods: </strong>The study involved 76 consecutive patients (51 males and 25 females) with mean age of 63.2 years who were treated with miniAVR between 2015 and 2022. They were divided into 2 subgroups: group I (<i>n</i> = 40) subjects with sutureless bioprostheses and group II (<i>n</i> = 36) with standard prostheses implanted. Early and mid-term outcomes were evaluated. A probability of survival was estimated by means of the Kaplan-Meier method.</p><p><strong>Results: </strong>No conversion to complete sternotomy was necessary. The median (minimum; maximum) aorta cross clamping and cardio-pulmonary bypass times were 49 (27; 84) and 70 (40; 188) minutes in group I whereas 69 (50; 103) and 95 (69; 170) minutes in group II, respectively (<i>p</i> < 0.001). In-hospital mortality was 5.0% (<i>n</i> = 2) and 2.8% (<i>n</i> = 1) in group I vs. II, respectively (ns). Permanent ICD implantation was performed in 8 (20.0%) in group I and in 3 (8.3%) subjects in group II. In the discharge echocardiography, the function of all prostheses was correct. Five-year probability of survival was much lower in group I (0.75 ±0.10) than in group II (0.94 ±0.04). No wound infection or sternum instability was noted.</p><p><strong>Conclusions: </strong>Intraoperative advantages of miniAVR procedures for aortic valve patients with sutureless bioprostheses do not translate directly into improved early and middle-term outcomes.</p>","PeriodicalId":49945,"journal":{"name":"Kardiochirurgia I Torakochirurgia Polska","volume":"20 2","pages":"77-82"},"PeriodicalIF":0.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/93/ad/KITP-20-51117.PMC10410630.pdf","citationCount":"0","resultStr":"{\"title\":\"A comparative study of minimally invasive aortic valve replacement with sutureless biological versus mechanical prostheses.\",\"authors\":\"Michał Bociański, Mateusz Puślecki, Anna Olasińska-Wiśniewska, Bartłomiej Perek, Sebastian Stefaniak, Piotr Buczkowski, Marek Jemielity\",\"doi\":\"10.5114/kitp.2023.129542\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The ministernotomy approach with sutureless aortic bioprosthesis may provide an attractive and safe option for aortic valve disease patients.</p><p><strong>Aim: </strong>To assess the early and mid-term outcomes of minimally invasive aortic valve replacement (miniAVR) with sutureless vs. standard prostheses.</p><p><strong>Material and methods: </strong>The study involved 76 consecutive patients (51 males and 25 females) with mean age of 63.2 years who were treated with miniAVR between 2015 and 2022. They were divided into 2 subgroups: group I (<i>n</i> = 40) subjects with sutureless bioprostheses and group II (<i>n</i> = 36) with standard prostheses implanted. Early and mid-term outcomes were evaluated. A probability of survival was estimated by means of the Kaplan-Meier method.</p><p><strong>Results: </strong>No conversion to complete sternotomy was necessary. The median (minimum; maximum) aorta cross clamping and cardio-pulmonary bypass times were 49 (27; 84) and 70 (40; 188) minutes in group I whereas 69 (50; 103) and 95 (69; 170) minutes in group II, respectively (<i>p</i> < 0.001). In-hospital mortality was 5.0% (<i>n</i> = 2) and 2.8% (<i>n</i> = 1) in group I vs. II, respectively (ns). Permanent ICD implantation was performed in 8 (20.0%) in group I and in 3 (8.3%) subjects in group II. In the discharge echocardiography, the function of all prostheses was correct. Five-year probability of survival was much lower in group I (0.75 ±0.10) than in group II (0.94 ±0.04). No wound infection or sternum instability was noted.</p><p><strong>Conclusions: </strong>Intraoperative advantages of miniAVR procedures for aortic valve patients with sutureless bioprostheses do not translate directly into improved early and middle-term outcomes.</p>\",\"PeriodicalId\":49945,\"journal\":{\"name\":\"Kardiochirurgia I Torakochirurgia Polska\",\"volume\":\"20 2\",\"pages\":\"77-82\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/93/ad/KITP-20-51117.PMC10410630.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kardiochirurgia I Torakochirurgia Polska\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/kitp.2023.129542\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kardiochirurgia I Torakochirurgia Polska","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/kitp.2023.129542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
A comparative study of minimally invasive aortic valve replacement with sutureless biological versus mechanical prostheses.
Introduction: The ministernotomy approach with sutureless aortic bioprosthesis may provide an attractive and safe option for aortic valve disease patients.
Aim: To assess the early and mid-term outcomes of minimally invasive aortic valve replacement (miniAVR) with sutureless vs. standard prostheses.
Material and methods: The study involved 76 consecutive patients (51 males and 25 females) with mean age of 63.2 years who were treated with miniAVR between 2015 and 2022. They were divided into 2 subgroups: group I (n = 40) subjects with sutureless bioprostheses and group II (n = 36) with standard prostheses implanted. Early and mid-term outcomes were evaluated. A probability of survival was estimated by means of the Kaplan-Meier method.
Results: No conversion to complete sternotomy was necessary. The median (minimum; maximum) aorta cross clamping and cardio-pulmonary bypass times were 49 (27; 84) and 70 (40; 188) minutes in group I whereas 69 (50; 103) and 95 (69; 170) minutes in group II, respectively (p < 0.001). In-hospital mortality was 5.0% (n = 2) and 2.8% (n = 1) in group I vs. II, respectively (ns). Permanent ICD implantation was performed in 8 (20.0%) in group I and in 3 (8.3%) subjects in group II. In the discharge echocardiography, the function of all prostheses was correct. Five-year probability of survival was much lower in group I (0.75 ±0.10) than in group II (0.94 ±0.04). No wound infection or sternum instability was noted.
Conclusions: Intraoperative advantages of miniAVR procedures for aortic valve patients with sutureless bioprostheses do not translate directly into improved early and middle-term outcomes.
期刊介绍:
Polish Journal of Thoracic and Cardiovascular Surgery is a quarterly aimed at cardiologists, cardiosurgeons and thoracic surgeons. Includes the original works (experimental, research and development), illustrative and casuistical works about cardiology and cardiosurgery.