T Miller, L J Roik, T Kalimullina, S Samejima, C Shackleton, R N Malik, R Sachdeva, A V Krassioukov
{"title":"成人脊髓损伤患者准备重复使用导管的时间负担:一项横断面研究。","authors":"T Miller, L J Roik, T Kalimullina, S Samejima, C Shackleton, R N Malik, R Sachdeva, A V Krassioukov","doi":"10.1038/s41394-023-00596-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Cross-sectional OBJECTIVES: Neurogenic lower urinary tract dysfunction is common among people with spinal cord injury (SCI). Although single-use clean intermittent catheterization is recommended to facilitate routine bladder emptying, catheter re-use is common. Barriers associated with the preparation (i.e., cleaning) of catheters for re-use are unknown. This study examined barriers to catheter re-use in adult individuals with SCI by assessing (1) the time needed to clean a catheter, and (2) the perceived difficulty of the catheter cleaning routine.</p><p><strong>Setting: </strong>Laboratory METHODS: Twenty individuals with chronic SCI ( ≥ 1 year since injury; Group 1 = 10 with tetraplegia; Group 2 = 10 with paraplegia) completed the study. Using a standardized cleaning procedure (i.e., Milton method), catheter cleaning was timed for each participant. Perceived difficulty was assessed using a 5-point Likert scale. Functional impairment was assessed with the Upper Extremity Motor Score (UEMS).</p><p><strong>Results: </strong>Significant between-group differences were observed for total cleaning time (Group 1 = 1584.1 ± 179.8 s; Group 2 = 1321.0 ± 93.8 s, p = 0.004) and perceived difficulty [Group 1 = 2.6 (2, 3); Group 2 = 2 (1.7, 2.3), p = 0.028]. Total cleaning time was significantly correlated with UEMS (ρ = -0.709, p ≤ 0.001) and perceived difficulty (ρ = 0.468, p = 0.037). UEMS emerged as an independent predictor of total cleaning time (R<sup>2</sup> = 0.745, β = -0.833, p ≤ 0.001).</p><p><strong>Conclusions: </strong>Preparing catheters for re-use is time-intensive and difficult for people with higher SCI level, severity and more pronounced upper limb motor impairment, which was independently associated with total cleaning time. Performing this routine on a consistent basis would require a substantial time commitment and would have a profoundly negative impact on overall quality of life.</p>","PeriodicalId":22079,"journal":{"name":"Spinal Cord Series and Cases","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10393987/pdf/","citationCount":"0","resultStr":"{\"title\":\"The temporal burden of preparing catheters for re-use in adults with spinal cord injury: a cross-sectional study.\",\"authors\":\"T Miller, L J Roik, T Kalimullina, S Samejima, C Shackleton, R N Malik, R Sachdeva, A V Krassioukov\",\"doi\":\"10.1038/s41394-023-00596-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Cross-sectional OBJECTIVES: Neurogenic lower urinary tract dysfunction is common among people with spinal cord injury (SCI). Although single-use clean intermittent catheterization is recommended to facilitate routine bladder emptying, catheter re-use is common. Barriers associated with the preparation (i.e., cleaning) of catheters for re-use are unknown. This study examined barriers to catheter re-use in adult individuals with SCI by assessing (1) the time needed to clean a catheter, and (2) the perceived difficulty of the catheter cleaning routine.</p><p><strong>Setting: </strong>Laboratory METHODS: Twenty individuals with chronic SCI ( ≥ 1 year since injury; Group 1 = 10 with tetraplegia; Group 2 = 10 with paraplegia) completed the study. Using a standardized cleaning procedure (i.e., Milton method), catheter cleaning was timed for each participant. Perceived difficulty was assessed using a 5-point Likert scale. Functional impairment was assessed with the Upper Extremity Motor Score (UEMS).</p><p><strong>Results: </strong>Significant between-group differences were observed for total cleaning time (Group 1 = 1584.1 ± 179.8 s; Group 2 = 1321.0 ± 93.8 s, p = 0.004) and perceived difficulty [Group 1 = 2.6 (2, 3); Group 2 = 2 (1.7, 2.3), p = 0.028]. Total cleaning time was significantly correlated with UEMS (ρ = -0.709, p ≤ 0.001) and perceived difficulty (ρ = 0.468, p = 0.037). UEMS emerged as an independent predictor of total cleaning time (R<sup>2</sup> = 0.745, β = -0.833, p ≤ 0.001).</p><p><strong>Conclusions: </strong>Preparing catheters for re-use is time-intensive and difficult for people with higher SCI level, severity and more pronounced upper limb motor impairment, which was independently associated with total cleaning time. Performing this routine on a consistent basis would require a substantial time commitment and would have a profoundly negative impact on overall quality of life.</p>\",\"PeriodicalId\":22079,\"journal\":{\"name\":\"Spinal Cord Series and Cases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10393987/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spinal Cord Series and Cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1038/s41394-023-00596-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spinal Cord Series and Cases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s41394-023-00596-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
The temporal burden of preparing catheters for re-use in adults with spinal cord injury: a cross-sectional study.
Study design: Cross-sectional OBJECTIVES: Neurogenic lower urinary tract dysfunction is common among people with spinal cord injury (SCI). Although single-use clean intermittent catheterization is recommended to facilitate routine bladder emptying, catheter re-use is common. Barriers associated with the preparation (i.e., cleaning) of catheters for re-use are unknown. This study examined barriers to catheter re-use in adult individuals with SCI by assessing (1) the time needed to clean a catheter, and (2) the perceived difficulty of the catheter cleaning routine.
Setting: Laboratory METHODS: Twenty individuals with chronic SCI ( ≥ 1 year since injury; Group 1 = 10 with tetraplegia; Group 2 = 10 with paraplegia) completed the study. Using a standardized cleaning procedure (i.e., Milton method), catheter cleaning was timed for each participant. Perceived difficulty was assessed using a 5-point Likert scale. Functional impairment was assessed with the Upper Extremity Motor Score (UEMS).
Results: Significant between-group differences were observed for total cleaning time (Group 1 = 1584.1 ± 179.8 s; Group 2 = 1321.0 ± 93.8 s, p = 0.004) and perceived difficulty [Group 1 = 2.6 (2, 3); Group 2 = 2 (1.7, 2.3), p = 0.028]. Total cleaning time was significantly correlated with UEMS (ρ = -0.709, p ≤ 0.001) and perceived difficulty (ρ = 0.468, p = 0.037). UEMS emerged as an independent predictor of total cleaning time (R2 = 0.745, β = -0.833, p ≤ 0.001).
Conclusions: Preparing catheters for re-use is time-intensive and difficult for people with higher SCI level, severity and more pronounced upper limb motor impairment, which was independently associated with total cleaning time. Performing this routine on a consistent basis would require a substantial time commitment and would have a profoundly negative impact on overall quality of life.